首页 | 本学科首页   官方微博 | 高级检索  
     

介入放射人员眼晶状体防护用品的选择和使用探讨
引用本文:于伟跃,陈法国,李国栋,韩毅. 介入放射人员眼晶状体防护用品的选择和使用探讨[J]. 中华放射医学与防护杂志, 2017, 37(8): 641-644
作者姓名:于伟跃  陈法国  李国栋  韩毅
作者单位:030006 太原, 中国辐射防护研究院科技与计划处,030006 太原, 中国辐射防护研究院保健物理研究所,030006 太原, 中国辐射防护研究院保健物理研究所,030006 太原, 中国辐射防护研究院保健物理研究所
摘    要:眼晶状体剂量限值的降低,使介入手术中职业人员的眼晶状体剂量监测和防护备受关注。基于文献中模拟计算和实验测量结果的调研,分析了介入人员眼晶状体防护用品的防护效果及影响因素,并提出了选择和使用建议。介入人员的眼晶状体剂量主要来自未被屏蔽而直接入射到眼部的射线;制约眼晶状体防护效果的重点不是铅当量厚度,而是防护用品结构、投照方位、位置布局、人员姿态等几何条件。0.5 mm铅当量对于介入人员眼晶状体防护是足够的;在临床实践中,组合使用铅眼镜和铅屏风能更好地对眼晶状体进行防护。

关 键 词:眼晶状体  防护用品  介入手术  职业人员
收稿时间:2017-03-23

Discussion on selection and use of eye lens protective equipment for interventional staff
Yu Weiyue,Chen Faguo,Li Guodong and Han Yi. Discussion on selection and use of eye lens protective equipment for interventional staff[J]. Chinese Journal of Radiological Medicine and Protection, 2017, 37(8): 641-644
Authors:Yu Weiyue  Chen Faguo  Li Guodong  Han Yi
Affiliation:Department of R & D and Planning, China Institute for Radiation Protection 030006 Taiyuan, China,Department of Health Physics, China Institute for Radiation Protection 030006 Taiyuan, China,Department of Health Physics, China Institute for Radiation Protection 030006 Taiyuan, China and Department of Health Physics, China Institute for Radiation Protection 030006 Taiyuan, China
Abstract:The decreased occupational dose limit for eye lens has lead to an extensive focus on the eye lens dose monitoring and protection for occupational staff in interventional procedures. Based on the literature investigation of existing measurement and calculation results, the efficiency and influence factors of eye lens protective equipments for interventional staff are analyzed, and the suggestions for selection and use of them are provided. The main contribution to the eye lens dose to interventional staff is unshielded radiation which reaches the eyes directly. The key factors to inflence the efficiency of eye lens protective equipment is the geometric conditions such as structure, beam projection, position arrangement and operator postures, instead of lead equivalent thickness. Equipment of 0.5 mm lead equivalent thickness is enough to protect the eye lens of interventional staff. The combination of lead glasses and lead barrier can provide better protection in clinical practice.
Keywords:Eye lens  Protective equipment  Interventional procedure  Occupational staff
点击此处可从《中华放射医学与防护杂志》浏览原始摘要信息
点击此处可从《中华放射医学与防护杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号