首页 | 本学科首页   官方微博 | 高级检索  
检索        


Advanced functional biomechanical analysis of medial rotation knee arthroplasty
Institution:1. Amsterdam UMC, Vrije Universiteit Amsterdam, Department of Rehabilitation Medicine, Amsterdam Movement Sciences, de Boelelaan 1117, Amsterdam, the Netherlands;2. Amsterdam UMC, University of Amsterdam, Musculoskeletal Imaging Quantification Center (MIQC), Department of Radiology and Nuclear Medicine, Amsterdam Movement Sciences, Meibergdreef 9, Amsterdam, the Netherlands;3. Delft University of Technology, Department of Biomechanical Engineering, Delft, the Netherlands;1. Centre for Health, Exercise and Sports Medicine, Department of Physiotherapy, School of Health Sciences, The University of Melbourne, VIC, Australia;2. Department of Epidemiology and Preventive Medicine, Monash University, VIC, Australia;3. The University of Melbourne, Department of Surgery, St Vincent''s Hospital, VIC, Australia;4. The University of Melbourne, Department of Orthopaedics, St. Vincent''s Hospital, VIC, Australia
Abstract:BackgroundThe Medacta GMK-Sphere total knee arthroplasty (TKA) is designed to mimic the movements and stabilimidty of a natural knee for optimal post-operative function and mobility. This study aimed to quantify the early functional outcome of patients with this implant.MethodsPatients due to undergo TKA to treat end-stage osteoarthritis were recruited into this study. Functional tests of knee range of motion (ROM), strength, and gait kinematics were carried out pre-operatively and one year post-operatively at routine clinics. Motion capture technology and a force transducer were used to collect all data. Normality tests were completed on all data sets to confirm normal distribution of the data, then paired t-tests were used to statistically compare the results. The level of significance was set as α = 0.05.ResultsSixty-three patients underwent pre-operative assessments; of which 30 returned one year post-operatively and consented to have follow-up testing. The operative knee was found to have poorer function than the contralateral knee pre-operatively (p < 0.05). Post-operatively, knee ROM significantly improved on the operative side to a mean of 116.1 ± 19.0. Gait kinematics also improved, especially in the frontal plane, but some abnormal traits remained in the sagittal plane. Knee strength decreased post-operatively.ConclusionsThe Medacta GMK-Sphere TKA improves knee range of motion sufficiently within the first postoperative year to allow patients to carry out most activities of daily living (> 110° knee flexion), but continued poor knee strength may limit their abilities to complete tasks which are more biomechanically demanding than walking.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号