首页 | 本学科首页   官方微博 | 高级检索  
检索        

中文版器官移植患者症状发生和症状困扰量表的信度及效度检验
引用本文:金三丽,谢双怡,路潜,庞冬,杨萍,刘丹.中文版器官移植患者症状发生和症状困扰量表的信度及效度检验[J].中国护理管理,2013(9):21-24.
作者姓名:金三丽  谢双怡  路潜  庞冬  杨萍  刘丹
作者单位:1. 北京大学护理学院,100191
2. 北京大学第一医院泌尿外科
摘    要:目的:翻译英文版器官移植患者症状发生和症状困扰量表(MTSOSD)并检验其信度及效度。方法:在征得原作者同意后,取得英文版MTSOSD,通过翻译和本土化形成中文版MTSOSD。采用中文版MTSOSD、健康相关生活质量问卷(SF-36)及医院焦虑抑郁量表中的抑郁分量表对106例肾移植患者进行测评,根据是否抑郁患者的症状评分判断工具的区分效度,根据症状与生活质量之间的相关性判断工具的校标关联效度;在1周后对12例患者进行二次测评,根据两次测评的相关性判断工具的重测信度。结果:抑郁组患者的症状发生总分及症状困扰总分均高于非抑郁组患者,差异有统计学意义(P〈0.01);106例患者的症状发生总分、症状困扰总分与除外“生理功能”的SF-36各维度得分均呈显著负相关,相关系数为-0.391~-0.510(P〈0.01);中文版MTSOSD的Cronbach’sα系数为0.897(按照症状发生情况)和0.919(按照症状困扰情况),重测信度系数为0.825(按照症状发生情况)和0.817(按照症状困扰情况)。结论:中文版MTSOSD具有较好的信度和效度,适用于在临床中测评器官移植患者免疫抑制治疗的相关症状。

关 键 词:器官移植  症状  效度  信度

Reliability and validity of the Chinese version of "Modiifed Transplant Symptom Occurrence and Symptom Distress Scale"
Institution:JIN San-li, XIE Shuang-yi, LU Qian, et al. // School of Nursing, Peking University, Beijing, 100191 China
Abstract:Objective:To translate the"Modiifed Transplant Symptom Occurrence and Symptom Distress Scale"(MTSOSD) into Chinese version, and test its reliability and validity. Methods:We obtained the English version of MTSOSD with the consent of the author. Then, the Chinese version of MTSOSD is formed by translation and localization. Totally 106 renal transplant patients were investigated by the Chinese version of MTSOSD, Short Form 36 Health Survey Questionnaire (SF-36) and the depression sub-scale of Hospital Anxiety and Depression Scale (HAD). Discriminant validity of the scale is tested by comparing symptom occurrence and distress in patients with/without depressive symptoms. The criterion-related validity is tested by relations between scores of SF-36 and symptom occurrence/distress. Then test-retest reliability was obtained by retesting 12 patients after one week. Results:Patients with depressive symptoms had a signiifcantly higher symptom occurrence and symptom distress compared to patients without depressive symptoms (P〈0.01). The symptom occurrence score and distress score were both negatively correlated with all the dimensions of SF-36 except physical function (P〈0.01). The Cronbach'sαof the scale was 0.897 (according to symptom occurrence) and 0.919 (according to symptom distress). The test-retest reliability was 0.825 (according to symptom occurrence) and 0.817 (according to symptom distress). Conclusion:The Chinese version of MTSOSD has good validity and reliability. It can be used for assessing associated symptoms of immunosuppressive drugs in transplant patients.
Keywords:organ transplantation  symptoms  validity  reliability
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号