首页 | 本学科首页   官方微博 | 高级检索  
     


Quantitative measurement and control of oxygen levels in microfluidic poly(dimethylsiloxane) bioreactors during cell culture
Authors:Geeta Mehta  Khamir Mehta  Dhruv Sud  Jonathan W. Song  Tommaso Bersano-Begey  Nobuyuki Futai  Yun Seok Heo  Mary-Ann Mycek  Jennifer J. Linderman  Shuichi Takayama
Affiliation:(1) Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48108, USA;(2) Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48108, USA;(3) Macromolecular Science and Engineering, University of Michigan, Ann Arbor, MI 48108, USA;(4) Applied Physics Program, University of Michigan, Ann Arbor, MI 48108, USA;(5) Comprehensive Cancer Center, University of Michigan, Ann Arbor, MI 48108, USA
Abstract:Microfluidic bioreactors fabricated from highly gas-permeable poly(dimethylsiloxane) (PDMS) materials have been observed, somewhat unexpectedly, to give rise to heterogeneous long term responses along the length of a perfused mammalian cell culture channel, reminiscent of physiologic tissue zonation that arises at least in part due to oxygen gradients. To develop a more quantitative understanding and enable better control of the physical-chemical mechanisms underlying cell biological events in such PDMS reactors, dissolved oxygen concentrations in the channel system were quantified in real time using fluorescence intensity and lifetime imaging of an oxygen sensitive dye, ruthenium tris(2,2’-dipyridyl) dichloride hexahydrate (RTDP). The data indicate that despite oxygen diffusion through PDMS, uptake of oxygen by cells inside the perfused PDMS microchannels induces an axial oxygen concentration gradient, with lower levels recorded in downstream regions. The oxygen concentration gradient generated by a balance of cellular uptake, convective transport by media flow, and permeation through PDMS in our devices ranged from 0.0003 (mg/l)/mm to 0.7 (mg/l)/mm. The existence of such steep gradients induced by cellular uptake can have important biological consequences. Results are consistent with our mathematical model and give insight into the conditions under which flux of oxygen through PDMS into the microchannels will or will not contribute significantly to oxygen delivery to cells and also provide a design tool to manipulate and control oxygen for cell culture and device engineering. The combination of computerized microfluidics, in situ oxygen sensing, and mathematical models opens new windows for microphysiologic studies utilizing oxygen gradients and low oxygen tensions. Electronic Supplementary Material is available in the online version of this article at
Keywords:Oxygen sensing  PDMS  Microbioreactor  Microfluidics  Fluorescence intensity  Fluorescence lifetime imaging microscopy (FLIM)  Oxygen gradients  Myoblast  Ruthenium tris(2,2’  -dipyridyl) dichloride hexahydrate (RTDP)
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号