首页 | 本学科首页   官方微博 | 高级检索  
     

实时灰阶超声造影评价肝移植术前门脉系统栓子的价值
引用本文:顾莉红,李凤华,李萍,朱彩霞,方华,杜晶,唐韵. 实时灰阶超声造影评价肝移植术前门脉系统栓子的价值[J]. 中国医学影像技术, 2008, 24(4): 557-559
作者姓名:顾莉红  李凤华  李萍  朱彩霞  方华  杜晶  唐韵
作者单位:上海交通大学医学院附属仁济医院超声科,上海,200127
摘    要:目的探讨实时灰阶超声造影在肝移植术前门脉系统栓子诊断及良恶性鉴别诊断中的价值。方法应用SonoVue造影剂及对比脉冲序列(CPS)技术对37例肝移植术前门脉系统栓子患者,共84条血管进行低机械指数实时灰阶超声造影检查。结果经过肝移植手术或螺旋CT门静脉成像证实,78条血管栓子形成(瘤栓50个,血栓28个),6条血管通畅。超声造影诊断门脉系统栓子的敏感性98.7%,特异性100%,以栓子内动脉相早期造影剂灌注为标准,诊断门脉系统瘤栓的敏感性100%,特异性100%。结论实时灰阶超声造影可评价肝移植术前门脉系统的通畅性,提高栓子的检出率,并可鉴别栓子的良恶性,为肝移植手术方案的确定提供重要准确的信息。

关 键 词:造影剂  超声检查  肝移植  门脉系统  门静脉栓子  实时灰阶超声造影  评价  肝移植术  门脉系统  栓子  价值  liver transplantation  thrombosis  system  venous  portal  diagnosis  ultrasound  信息  手术方案  鉴别  检出率  通畅性  标准  灌注
文章编号:1003-3289(2008)04-0557-03
收稿时间:2007-09-12
修稿时间:2007-09-12

The value of real-time gray-scale contrast-enhanced ultrasound in diagnosis of portal venous system thrombosis before liver transplantation
GU Li-hong,LI Feng-hu,LI Ping,ZHU Cai-xi,FANG Hu,DU Jing and TANG Yun. The value of real-time gray-scale contrast-enhanced ultrasound in diagnosis of portal venous system thrombosis before liver transplantation[J]. Chinese Journal of Medical Imaging Technology, 2008, 24(4): 557-559
Authors:GU Li-hong  LI Feng-hu  LI Ping  ZHU Cai-xi  FANG Hu  DU Jing  TANG Yun
Affiliation:Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200127, China;Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200127, China;Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200127, China;Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200127, China;Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200127, China;Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200127, China;Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200127, China
Abstract:Objective To evaluate the value of gray-scale contrast-enhanced ultrasound (CEUS) in diagnosis and differential diagnosis of portal venous system thrombosis. Methods SonoVue-enhanced ultrasonography with contrast pulsed sequencing (CPS) imaging technique was performed on 84 vessels of 37 patients with portal vein system thrombosis before liver transplantation. Results Seventy-eight vessels with thrombosis (50 tumor thrombosis, 28 blood thrombosis) and 6 with normal lumens were confirmed by liver transplant surgery or spiral CT portography. The sensitivity and specificity in diagnosis of portal vein thrombosis with contrast-enhanced ultrasonography were 98.7% and 100%, respectively. Using early arterial enhancement of the thrombus on CEUS as a criterion, for the diagnosing protal venous thrombosis, the sensitivity and specificity were 100% and 100%, respectively. Conclusion CEUS can improve the detecting rate of portal venous system thrombosis and differentiate blood thrombosis from tumor thrombosis. It can be the guide for the clinicians to choose proper methods before liver transplantation.
Keywords:Contrast media  Ultrasonography  Liver transplantation  Portal venous system  Portal vein thrombosis
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号