首页 | 本学科首页   官方微博 | 高级检索  
检索        


Radiographic evaluation of linear wear of bipolar hemiarthroplasty devices in vivo
Institution:1. Department of Orthopaedics, Nizam’s Institute of Medical sciences, Punjagutta, Hyderabad, Telangana 500082, India;2. Department of Biochemistry, Nizam’s Institute of Medical sciences, Punjagutta, Hyderabad, Telangana 500082, India;3. Department of Radiology, Nizam’s Institute of Medical sciences, Punjagutta, Hyderabad, Telangana 500082, India
Abstract:BackgroundThe indications for bipolar hemiarthroplasty (BHA) have been narrowing as those for total hip arthroplasty (THA) have been expanding in cases of femoral neck fracture and initial stages of osteonecrosis of femoral head (ONFH). It is difficult to measure wear in vivo after BHA because the equipment used has a dual bearing system with an inner head inside a metal outer cup. The present study aimed to (1) use a roentgenograph to measure linear wear in vivo after BHA with different acetabular conditions around the bipolar cup, and (2) compare the linear wear of polyethylene between integral bipolar cup (IBC) and Centrax prostheses.MethodsFrom among patients who had undergone BHA in our department after 1996, we analyzed 48 joints with osteoarthritis (OA) and without acetabular cartilage, as well as 25 joints with ONFH of stage 3 or less, in which the acetabular cartilage remains. Two types of bipolar cup prostheses were used: the IBC, which was gamma-sterilized in air using 2-Mrad irradiation, and the Centrax, which was gamma-sterilized in nitrogen using 3-Mrad irradiation. To image the inner head in vivo, we used high-pressure X-ray photography; we measured linear wear of the polyethylene with software using Martell Method 1.ResultsComparing mean annual linear wear between the OA and ONFH groups, using IBC prostheses in both groups, there was a significant difference (0.213 mm vs. 0.096 mm, respectively; P = 0.0177). There was a significant difference between the Centrax and IBC prostheses in OA patients in terms of linear wear (0.04 mm vs. 0.213 mm; P = 0.0181).ConclusionThe linear wear of polyethylene in BHA implants can be affected by the material used to manufacture the bipolar cup. Such implants should only be used for appropriate indications.
Keywords:Hemiarthroplasty  Hip  Polyethylene wear  Radiography  BHA"}  {"#name":"keyword"  "$":{"id":"kwrd0040"}  "$$":[{"#name":"text"  "_":"bipolar hemiarthroplasty  THA"}  {"#name":"keyword"  "$":{"id":"kwrd0050"}  "$$":[{"#name":"text"  "_":"total hip arthroplasty  IBC"}  {"#name":"keyword"  "$":{"id":"kwrd0060"}  "$$":[{"#name":"text"  "_":"integral bipolar cup  OA"}  {"#name":"keyword"  "$":{"id":"kwrd0070"}  "$$":[{"#name":"text"  "_":"osteoarthritis  ONFH"}  {"#name":"keyword"  "$":{"id":"kwrd0080"}  "$$":[{"#name":"text"  "_":"osteonecrosis of the femoral head
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号