首页 | 本学科首页   官方微博 | 高级检索  
检索        


Clinical and radiological outcome after mini-open Latarjet technique with fixation of coracoid with Arthrex wedge mini-plate
Authors:Deepak Chaudhary  Ankit Goyal  Deepak Joshi  Vineet Jain  Mukul Mohindra  Nitin Mehta
Institution:1. Director, Sports Injury Center, Safdarjung Hospital and VMM College, New Delhi, India;2. Assistant Professor, Sports Injury Center, Safdarjung Hospital and VMM College, New Delhi, India;3. Specialist, Sports Injury Center, Safdarjung Hospital and VMM College, New Delhi, India;4. Associate Professor, Sports Injury Center, Safdarjung Hospital and VMM College, New Delhi, India;5. Fellow (Arthroscopy and Sports Medicine), Sports Injury Center, Safdarjung Hospital and VMM College, New Delhi, India;1. Senior Resident, Department of Orthopaedics, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India;2. Professor, Department of Orthopaedics, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India;3. Additional Professor, Department of Orthopaedics, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India;1. Senior Resident, Department of Orthopaedics, Maulana Azad Medical College and Lok Nayak Hospital, New Delhi, India;2. Assistant Professor, Department of Orthopaedics, Maulana Azad Medical College and Lok Nayak Hospital, New Delhi, India;1. Director Professional Services, Head of Surgery, Consultant Orthopaedics Trauma & Arthroplasty, P.D. Hinduja National Hospital and Medical Research Centre, Veer Savarkar Marg, Mahim, Mumbai 400016, India;2. Consultant Orthopaedics Trauma & Arthroplasty, Lad''s Bone & Joint Clinic, 4th Floor, Kailas Darshan, Kennedy Bridge, Nana Chowk, Mumbai 400026, India;3. Consultant Orthopaedics Trauma & Musculoskeletal Infection, P.D. Hinduja National Hospital and Medical Research Centre, Veer Savarkar Marg, Mahim, Mumbai 400016, India;4. Associate Consultant Orthopaedics Trauma & Arthroplasty, P.D. Hinduja National Hospital and Medical Research Centre, Veer Savarkar Marg, Mahim, Mumbai 400016, India;1. Sanford Orthopedics and Sports Medicine, Fargo, North Dakota, U.S.A.;2. Hospital for Special Surgery, New York, New York, U.S.A.;3. Department of Orthopedic Surgery, University of Michigan, Ann Arbor, Michigan, U.S.A.;1. Department of Orthopaedic Surgery, Showa University Fujigaoka Hospital, 1-30 Fujigaoka, Aoba-ku, Yokohama 227-8501, Japan;2. Department of Sports Medicine and Orthopaedic Surgery, Showa University Fujigaoka Rehabilitation Hospital, 2-2-1 Fujigaoka, Aoba-ku, Yokohama 227-8518, Japan;1. Professor, Department of Orthopedics, Government Medical College and Hospital, Chandigarh, India;2. Senior Resident, Department of Orthopedics, Government Medical College and Hospital, Chandigarh, India
Abstract:BackgroundTechnical faults leading to coracoid fractures during screw insertion and coracoid graft osteolysis are concerns with standard screw fixation techniques in Latarjet procedure. The purpose of this study is to share our experience using Arthrex wedge profile plate with mini-open technique for graft fixation, that ensures better load distribution between coracoid graft and glenoid.MethodsWe did retrospective analysis of 24 patients with recurrent anterior shoulder instability after failed arthroscopic Bankart's repair. Arthroscopic examination of affected shoulder was done in lateral position before making patient supine for open Latarjet. A low profile wedge plate (Arthrex) with two screws was used for the procedure. CT analysis was performed post-operatively at 6 months to see graft union and results were evaluated using the Rowe and Walch Duplay score.ResultsMean follow-up time was 26 months. Postoperatively, mean forward elevation was 170.6 + 4.6° (loss of average 5.9°) and mean external rotation was 42.5 + 5.3° (loss of average 3.1°). All patients returned to their previous occupation. None reported to be having any recurrent subluxation. Functional assessment done using Rowe score and Walch Duplay score showed statistically significant improvement (p value 0.034). There were no implant-related complications and no case of coracoid graft osteolysis.ConclusionsMini-open Latarjet with graft fixation with Arthrex mini-plate provides satisfactory outcome in patients who require reoperation due to dramatic bone loss and failed soft tissue reconstruction. The modified incision improves exposure enabling plate fixation and the secure fixation accelerates rehabilitation.
Keywords:Shoulder instability  Bankarts  Reoperation  Mini-open Latarjet  Wedge profile plate
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号