Influences of screw design features on initial stability in immediate implant placement and restoration
Institution:1. School of Dentistry, National Yang Ming Chiao Tung University, Taipei, Taiwan;2. Department of Dentistry, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan;3. Department of Medical Research, MacKay Memorial Hospital, New Taipei City, Taiwan;1. Third Faculty of Medicine, Charles University, Prague, Ruska 2411/87, 100 00 Praha 10-Vinohrady, Czech Republic;2. Regional Hospital in Liberec, Husova 10, Liberec 46001, Czech Republic;3. Colleague of Polytechnics Jihlava, Tolsteho 1556, Jihlava 58601, Czech Republic;4. Technical University of Liberec, Studentska 2, Liberec 46117, Czech Republic;1. Department of Orthopaedic Surgery, Woodlands Health, Singapore;2. School of Mechanical & Aerospace Engineering, College of Engineering, Nanyang Technological University, Singapore;3. Department of Orthopaedic Surgery, Khoo Teck Puat Hospital, Singapore
Abstract:BackgroundSelf-tapping screws have been extensively used for dental implants. Their biomechanical behavior is highly associated with their clinical success, particularly for screws used for immediate implant placement and restoration, because occlusal forces can directly affect the loading transfer at the bone–implant interface after implantation. The effect of implant design on the initial stability of self-tapping screws remains unclear. This study explored the biomechanical behaviors of implant stability in standardized implants with different design features.MethodsSix types of dental implants were designed using computer-aided design/computer-aided manufacturing technology, including three types of cutting flute shapes (spiral, straight, and non–self-tapping) combined with two types of screw features. Peak insertion torque values were first recorded; initial stability levels were subsequently evaluated in terms of the maximum force and resistance to lateral loads using an electrodynamic test system.FindingsThe peak insertion torque values, maximum force, and resistance to lateral loads of the non–self-tapping groups were higher than those of the self-tapping groups by 17%–90% (p < 0.01). The peak insertion torque values of the Straumann implant with a spiral flute was higher than that of the original straight flute by 20% (p < 0.001). However, compared with the original spiral flute, the Nobel Biocare implant with straight flute had a 23% higher maximum force (p = 0.016) and 24.5% higher resistance (p = 0.012) under lateral loading.InterpretationChanging the flute design would affect initial implant stability. Non–self-tapping implants exhibited superior initial stability than did self-tapping implants.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号