基于时频分布的表面肌电信号瞬时中值频率的研究
引用本文:梁政,杨基海,钱晓进,陈香,叶硃,荣蓓钰,谭春祥,冯焕清. 基于时频分布的表面肌电信号瞬时中值频率的研究[J]. 航天医学与医学工程, 2004, 17(1): 54-58
作者姓名:梁政  杨基海  钱晓进  陈香  叶硃  荣蓓钰  谭春祥  冯焕清
作者单位:中国科学技术大学电子科学与技术系,安徽合肥,230026;中国科学技术大学电子科学与技术系,安徽合肥,230026;中国科学技术大学电子科学与技术系,安徽合肥,230026;中国科学技术大学电子科学与技术系,安徽合肥,230026;中国科学技术大学电子科学与技术系,安徽合肥,230026;中国科学技术大学电子科学与技术系,安徽合肥,230026;中国科学技术大学电子科学与技术系,安徽合肥,230026;中国科学技术大学电子科学与技术系,安徽合肥,230026
摘    要:目的 采用时频分析法分析表面肌电信号瞬时中值频率。方法 采用平滑伪-魏格纳分布、乔伊-威廉姆斯分布、谱图和尺度图等方法,估计模拟和真实表面肌电信号的瞬时中值频率,讨论这些分布在估计肌电信号瞬时中值频率时的性能,并与条件平均频率进行比较。结果 模拟实验表明瞬时中值频率曲线比条件平均频率曲线光滑,相对误差较小。真实肌电信号实验显示,在肌肉收缩过程中,瞬时中值频率比条件平均频率的波动更明显。结论 肌电信号瞬时中值频率比条件平均频率更能真实和敏感地反映表面肌电信号频率成分的变化。

关 键 词:瞬时中值频率  时频分布  肌电图  表面肌电信号
文章编号:1002-0837(2004)01-0054-05

A Study on Instantaneous Median Frequency of Surface EMG Signals Based on Time-frequency Distributions
LIANG Zheng,YANG Ji hai,QIAN Xiao jin,CHEN Xiang,YE Zhu,RONG Bei yu,TAN Chun xiang,FENG Huan qing. A Study on Instantaneous Median Frequency of Surface EMG Signals Based on Time-frequency Distributions[J]. Space Medicine & Medical Engineering, 2004, 17(1): 54-58
Authors:LIANG Zheng  YANG Ji hai  QIAN Xiao jin  CHEN Xiang  YE Zhu  RONG Bei yu  TAN Chun xiang  FENG Huan qing
Affiliation:LIANG Zheng,YANG Ji hai,QIAN Xiao jin,CHEN Xiang,YE Zhu,RONG Bei yu,TAN Chun xiang,FENG Huan qing. Department of Electronic Science and Technology,USTC,Hefei 230026,China
Abstract:Objective Median frequency of EMG signal is a significant physiological parameter of the neural muscular system. Due to the non stationarity of EMG signal, the methods such as periodogram and parameters model may not be suitable for frequency analysis of EMG signal. We use the time frequency analysis method to detect the instantaneous frequency components of EMG signal. Method The concept of instantaneous median frequency surface EMG signal was discussed. The instantaneous median frequency of simulated and real surface EMG signals were estimated and compared with the conditional mean frequency by means of the methods of time frequency analysis including smoothed pseudo Wigner Ville distribution, the Choi Williams distribution, spectrograms and scalograms. Advantages and drawbacks of the involved methods were compared. Result Both the instantaneous median frequency and conditional frequency could track the change of the frequency components of the simulated EMG signal, but the former was smoother than the latter and had smaller relative errors. Experiments with real surface EMG signal showed that the instantaneous median frequency changes more apparently than the conditional frequency during the process of sustained muscle contractions. Further more, the performance of estimation methods aforementioned could be improved by choosing an appropriate type of window and its width. Conclusion The instantaneous median frequency could indicate the change of the frequency component of surface EMG signal more accurately and sensitively than the conditional mean frequency.
Keywords:instantaneous median frequency  time frequency distribution  electromyograph  surface EMG signals