摘    要:目的 探讨标本在实验室中放置时间过长,受日光和灯光照射,对总胆红素测定结果的影响.方法 将一组标本暴露在实验室日光和灯光下,一组标本避光保存,2 h后测定两组标本的血浆总胆红素值,对比分析两组标本测定结果的平均偏差.结果 受日光灯光照射组的总胆红素值明显下降,两组测定结果对比差异有统计学意义(P<0.01).结论 待测标本较多时,为减少胆红素的自发性氧化和光氧化而使胆红素测定结果偏低,标本采集后应立即测定胆红素,待测标本在上机测定前应置2~8 ℃冰箱中避光保存,防止标本中胆红素的氧化而影响测定结果.

关 键 词:胆红素氧化  光线照射  影响

Bilirubin test specimens exposed to laboratory light affects detection results
SHEN Xue-geng.Bilirubin test specimens exposed to laboratory light affects detection results[J].Laboratory Medicine and Clinic,2012,9(3):285-285,287.
Authors:SHEN Xue-geng
Institution:SHEN Xue-geng
Abstract:Objective Due to the spontaneous oxidation and photo-oxidation effect of bilirubin,placing the samples in the lab too long,to investigate the influence of sun and light exposure on the detection results of total bilirubin.Methods A group of specimens were exposed to sunlight and lamplight in the laboratory and another group of specimens were stored avoiding light.2 h later,the two groups of samples were detected plasma total bilirubin.The average deviation of the detection results in the two groups were analyzed.Results The total bilirubin value in the fluorescent light irradiation group was significantly decreased,showing statistical difference between the two groups(P<0.01).Conclusion In many specimens for testing,in order to reduce the detection results too low due to spontaneous oxidation and photo-oxidation of bilirubin,the specimen should be immediately detected bilirubin after collection,and the specimen for test should be stored at 2-8℃ protected from light in refrigerator before detection in the machine to prevent the oxidation of bilirubin in the specimen affecting the detection results.
Keywords:bilirubin oxidation  light irradiation  impact
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号