首页 | 本学科首页   官方微博 | 高级检索  
     


Covered Stents in the Treatment of Peripheral Arterial Aneurysms: Procedural Results and Midterm Follow-Up
Authors:Jean-Paul Beregi  Alain Prat  Serge Willoteaux  Marc-Antoine Vasseur  Valérie Boularand  Frédéric Desmoucelle
Affiliation:Service de Radiologie, H?pital Cardiologique, CHRU de Lille, F-59037 Lille, France, FR
Service de Chirurgie Cardio-Vasculaire A, H?pital Cardiologique, CHRU de Lille, F-59037 Lille, France, FR
Abstract:Purpose: To evaluate initial and midterm results of percutaneous treatment of peripheral aneurysms using covered stents. Methods: Between June 1994 and December 1997 we used covered stents (EndoPro System or Passager) on 19 patients with peripheral aneurysms (7 iliac, 5 subclavian, 3 femoral, 3 popliteal, 1 carotid). Results: Successful aneurysm exclusion was achieved in 18 of 19 patients (95%). In the short term (<30 days), one patient died of puncture site hemorrhage complicated by myocardial infarction; two femoral stents were surgically removed because of leakage. At subsequent follow-up (mean 20 months) two further unrelated deaths occurred. At 1 year (intention-to-treat) the stent was patent in 13 of 19 patients (68%) and the aneurysm was excluded in 17 of 19 (89%). Conclusion: Treatment of peripheral aneurysms with covered stents has a high rate of immediate procedural success. Continued exclusion of the aneurysms is achieved in a large proportion of patients but there is a relatively high rate of stent thrombosis.
Keywords:: Aneurysm, iliac—  Aneurysm, femoral—  Aneurysm, therapy—  Stents and prostheses
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏