首页 | 本学科首页   官方微博 | 高级检索  
检索        


Viscoelastic and failure properties of two configurations of triple-folded hamstring tendons used for anterior cruciate ligament (ACL) reconstruction
Institution:1. Department of Orthopaedics and Sports Medicine, University of South Florida, Tampa, FL, USA;2. USF Health Morsani College of Medicine, University of South Florida, Tampa, FL, USA;3. Foundation for Orthopaedic Research and Education, Tampa, FL, USA;1. Ac?badem Maslak Hospital, Istanbul, Turkey;2. Department of Orthopaedics and Traumatology Ata?ehir, Ac?badem Mehmet Ali Ayd?nlar University School of Medicine, Istanbul, Turkey;3. Istanbul Faculty of Medicine, Department of Orthopaedics and Traumatology, Istanbul University, Fatih Istanbul, Turkey;1. Tianjin Hospital, Tianjin, China;2. Second Hospital of Tangshan, Hebei, China;3. Graduate School, Tianjin Medical University, Tianjin, China;4. Beijing Weigao Yahua Artificial Joint Development Company, Beijing, China;1. University of Edinburgh, Edinburgh, UK;2. Royal Infirmary of Edinburgh, Edinburgh, UK
Abstract:BackgroundHamstring autografts are commonly used for anterior cruciate ligament (ACL) reconstruction. Different folding techniques exist in tripling the semitendinosus. Few anatomical studies exist in evaluating their viscoelastic properties. The purpose of this study was to characterize and compare the viscoelastic and failure properties of two hamstring graft configurations, the “Z” construct and “2” construct.MethodsTen matched pairs of fresh-frozen cadaveric semitendinosus hamstring grafts were used to create the “2” configuration or “Z” configuration. The biomechanical testing consisted of four phases: preconditioning, where graft dimensions (mm) were measured; stress relaxation, where load, displacement and time data were collected and equilibrium relaxation (%) was calculated; dynamic creep, where the total construct elongation was calculated; and ramp-to-failure, where maximum failure load was recorded.ResultsThe “2” configuration demonstrated recorded forces (N) significantly greater at each time point when compared to the “Z” configuration during stress relaxation (p = 0.003). The “2” configuration exhibited significantly less construct elongation (mm) during dynamic creep at 10 cycles (p = 0.008) and 2000 cycles (p = 0.0001). The maximum measured load at failure was significantly greater in the “2” configuration constructs than “Z” configuration (p = 0.013). Moreover, the axial loads at 2, 3 and 4 mm of displacement were, on average, greater in the “2” configuration than “Z” configuration (p = 0.152; p = 0.080; p = 0.012), respectively.ConclusionThe results of this study provide support for folding techniques for tripled grafts to provide higher viscoelastic and failure properties for techniques with less suture interfaces. Future studies can potentially evaluate the clinical significance of these findings.
Keywords:ACL reconstruction  Autografts  Semitendinosus  Hamstring
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号