Affiliation:1. Department of Orthopaedic Surgery, Hyogo College of Medicine, Japan;2. Department of Orthopaedic Surgery, Nishinomiya Kaisei Hospital, Japan;3. Diakonie Klinikum Jung-Stilling, Siegen, Germany;1. Second Department of Orthopaedic Surgery, Dokkyo Medical University Saitama Medical Center, Saitama, Japan;2. Department of Orthopaedic Surgery, Tokyo Medical and Dental University Hospital, Tokyo, Japan;3. Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, Hiroshima, Japan;1. Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan;2. Department of Orthopaedic Biomaterial Science, Osaka University Graduate School of Medicine, 2-2 Yamada-oka, Suita, Osaka 565-0871, Japan;3. Department of Information Systems, Faculty of Engineering, Saitama Institute of Technology, 1690 Fusaiji, Fukaya, Saitama 369-0293, Japan;1. Department of Orthopaedic Surgery, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan;2. Department of Orthopaedic Surgery, Matsumoto Medical Center, 2-20-30 Muraimachi Minami, Matsumoto, Nagano 399-8701, Japan;3. Department of Orthopaedic Surgery, Shinshu Ueda Medical Center, 1-27-21 Midorigaoka, Ueda, Nagano 386-8610, Japan
Abstract:BackgroundPatellar tendon rupture is a devastating complication after total knee arthroplasty (TKA). Different strategies have been used to reconstruct or augment direct repairs.MethodsAcute patellar tendon ruptures after TKA were treated using ultra-high molecular weight polyethylene cable (Nesplon cable) for augmentation in four patients. Nesplon cables were inserted anteriorly through the quadriceps just above the patella, and drill holes were placed in the tibial tubercle with one in figure-of-eight fashion and the other in cerclage configuration. Clinical evaluations were performed using range of motion and Knee Society Score at the time of last follow-up. Mean follow-up was 3.5 years.ResultsPostoperatively, mean flexion was 119° and mean extension was 0° in all cases. No knees showed extension lag. Mean knee score was 93.8 and mean function score was 63.8. Infection occurred in one case.ConclusionPatellar tendon reconstruction with Nesplon cable was favorable with good clinical outcomes.
Keywords:Patellar tendon rupture  Arthroplasty  Knee  Reconstruction  Ultra-high molecular weight polyethylene
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号