核素显像及磁共振灌注成像在诊断缺血性脑血管病中的对比研究
引用本文:何洁,卢洁,许英路,翟勇,张人玲,刘丹. 核素显像及磁共振灌注成像在诊断缺血性脑血管病中的对比研究[J]. 中国医学影像技术, 2006, 22(2): 281-283
作者姓名:何洁  卢洁  许英路  翟勇  张人玲  刘丹
作者单位:1. 首都医科大学宣武医院核医学科,北京,100053
2. 首都医科大学宣武医院放射科,北京,100053
摘    要:目的比较脑葡萄糖代谢显像、脑血流灌注显像及磁共振灌注成像三种检查方法在诊断缺血性脑血管病中的价值。方法对78例缺血性脑血管病患者和26例单侧脑血管病变患者的脑葡萄糖代谢显像、脑血流灌注显像及磁共振灌注成像进行对比分析。结果所有患者用脑葡萄糖代谢显像、脑血流灌注显像及磁共振灌注成像三种检查方法检出的阳性率分别为97.44%、94.87%和82.05%,脑葡萄糖代谢显像、脑血流灌注显像与灌注加权磁共振成像结果比较均有显著性差异(P值分别为0.012、0.002)。26例单侧血管病变患者用三种检查方法检出的阳性率分别为96.15%、92.31%、92.31%,三者无显著性差异(P=0.552)。结论脑葡萄糖代谢显像、脑血流灌注显像对诊断缺血性脑血管病较敏感,在诊断单侧血管病变中三种检查方法均较敏感。

关 键 词:脑缺血  体层摄影术  发射型计算机  符合线路  磁共振成像  灌注
文章编号:1003-3289(2006)02-0281-03
收稿时间:2005-09-12
修稿时间:2005-11-08

Comparison of nuclide imaging and MR perfusion weighted imagingin patients with ischemic cerebrovascular diseases
HE Jie,LU Jie,XU Ying-lu,ZHAI Yong,ZHANG Ren-ling and LIU Dan. Comparison of nuclide imaging and MR perfusion weighted imagingin patients with ischemic cerebrovascular diseases[J]. Chinese Journal of Medical Imaging Technology, 2006, 22(2): 281-283
Authors:HE Jie  LU Jie  XU Ying-lu  ZHAI Yong  ZHANG Ren-ling  LIU Dan
Affiliation:1. Department of Nuclear Medicine;2. Department of Radiology, Xuanzeu Hospital, Capital University of Medical Sciences, Beij ing 100053, China
Abstract:Objective To compare the diagnostic value of cerebral glucose metabolism imaging, cerebral blood flow perfusion imaging, and MR perfusion weighted imaging (PWI) in patients with ischemic cerebrovascular diseases. Methods We compared the results of 78 patients with ischemic cerebrovascular diseases and 26 patients with only single-side involvement who underwent all the three examinations. Results The positive rates of brain glucose metabolism imaging, cerebral blood flow perfusion imaging and PWI in 78 patients were 97.44%, 94.87% and 82.05%, respectively. Compared brain glucose metabolism imaging, brain blood flow perfusion imaging with PWI, there were significant differences (P=0.012 and 0.002, respectively). The positive rate of brain glucose metabolism imaging, cerebral blood flow perfusion imaging and PWI in 26 patients with single-side involvement were 96.15%, 92.31% and 92.31%, respectively, and there was no significant difference among them (P=0.552). Conclusion Brain glucose metabolism imaging and cerebral blood flow perfusion imaging were sensitive in diagnosing ischemic cerebrovascular diseases. But the three methods were all sensitive in diagnosing ischemic cerebrovascular diseases caused by single-side affected vessels.
Keywords:Brain ischemia  Tomography   emission-computed  Coincidence  Magnetic resonance imaging   perfusion