Radiofrequency Ablation Guided by Mechanical Termination of Idiopathic Ventricular Arrhythmias Originating in the Right Ventricular Outflow Tract |
| |
Authors: | MICHAEL KÜHNE MD JEAN-FRANCOIS SARRAZIN MD THOMAS CRAWFORD MD MATTHEW EBINGER DO ERIC GOOD DO AMAN CHUGH MD KRIT JONGNARANGSIN MD FRANK PELOSI Jr MD HAKAN ORAL MD FRED MORADY MD FRANK M BOGUN MD |
| |
Institution: | From the University of Michigan Health System, Ann Arbor, Michigan, USA |
| |
Abstract: | Mapping of Idiopathic Ventricular Arrhythmias. Background: Termination of ventricular tachycardia (VT) by mechanical pressure has been described for fascicular and postinfarction VT. Mechanical interruption of idiopathic ventricular arrhythmias (VT/premature ventricular complexes PVCs]) arising in the right ventricular outflow tract (RVOT) has not been described in systematic fashion. Methods: Eighteen consecutive patients (13 females, age 49 ± 13 years, ejection fraction 0.55 ± 0.12) underwent mapping and ablation of RVOT VT or PVCs. In 7 patients, 9 distinct VTs (mean cycle length 440 ± 127 ms), and in 11 patients, 11 distinct PVCs originating in the RVOT were targeted. Mechanical termination was considered present if a reproducibly inducible VT was no longer inducible or if frequent PVCs suddenly ceased with the mapping catheter at a particular location. Endocardial activation time, electrogram characteristics, and pace‐mapping morphology were assessed at this location. Radiofrequency energy was delivered if mechanical termination was observed. Results: All targeted arrhythmias were successfully ablated. In 7 of 18 patients (39%), catheter manipulation terminated the arrhythmia with the mapping catheter located at a particular site. Local endocardial activation time was earlier at sites of mechanical termination (?31 ± 7 ms) compared with effective sites without termination (?25 ± 3 ms, P = 0.04). The 10‐ms isochronal area was smaller in patients with mechanical interruption (0.35 ± 0.2 cm2) than in patients without mechanical termination (1.33 ± 0.9 cm2, P = 0.01). At all sites susceptible to mechanical trauma, the pace map displayed a match with the targeted VT/PVC. All sites where mechanical termination of VT or PVCs occurred were effective ablation sites. Conclusions: Mechanical suppression at the site of origin of idiopathic RVOT arrhythmias frequently occurs during the mapping procedure and is a reliable indicator of effective ablation sites. Mechanical termination of RVOT arrhythmias may be indicative of a more localized arrhythmogenic substrate. (J Cardiovasc Electrophysiol, Vol. 21, pp. 42–46, January 2010) |
| |
Keywords: | catheter ablation ventricular tachycardia right ventricular outflow tract catheter trauma premature ventricular complexes mapping |
|
|