首页 | 本学科首页   官方微博 | 高级检索  
     

数字化可摘局部义齿支架模型的建立与结构强度的有限元分析
引用本文:钱飞,吴玉禄,刁晓鸥,罗慧闻,李玉姣,汤忠斌,孙亚婷,马蕾,辛海涛. 数字化可摘局部义齿支架模型的建立与结构强度的有限元分析[J]. 实用口腔医学杂志, 2022, 0(1): 97-101
作者姓名:钱飞  吴玉禄  刁晓鸥  罗慧闻  李玉姣  汤忠斌  孙亚婷  马蕾  辛海涛
作者单位:军事口腔医学国家重点实验室;军事口腔医学国家重点实验室;西北工业大学航空学院
基金项目:陕西省重点研发计划项目(编号:2017ZDXM-SF-069)。
摘    要:目的:建立数字化可摘局部义齿支架模型,对其进行结构强度分析和形态优化。方法:通过3Shape Dental System软件设计上颌肯氏II类牙列缺损可摘局部义齿支架,使用Abaqus/CAE有限元软件分析支架受力及其对基牙、黏膜以及牙槽嵴的影响。结果:数字化模型精度高,支架结构完整、适合性较好。基于数字化支架建立的有限元模型相似性高。支架小连接体应力集中,远端下沉,缺隙侧基牙应力大于对侧基牙,缺牙区远端出现高应力区。有限元分析结果能够反应支架在口内的受力和运动情况。结论:运用有限元法对数字化支架进行分析和优化,能够完善数字化支架设计和制作过程。

关 键 词:数字化  可摘局部义齿  支架  有限元分析  3D打印

The structural strength analysis of the digital framework for removable partial denture using finite element method
QIAN Fei,WU Yulu,DIAO Xiaoou,LUO Huiwen,LI Yujiao,TANG Zhongbin,SUN Yating,MA Lei,XIN Haitao. The structural strength analysis of the digital framework for removable partial denture using finite element method[J]. Journal of Practical Stomatology, 2022, 0(1): 97-101
Authors:QIAN Fei  WU Yulu  DIAO Xiaoou  LUO Huiwen  LI Yujiao  TANG Zhongbin  SUN Yating  MA Lei  XIN Haitao
Affiliation:(State Key Laboratory of Military Stomatology&National Clinical Research Center for Oral Diseases&Shaanxi Key Laboratory of Stomatology,Department of Prosthodontics,School of Stomatology,The Fourth Military Medical University,710032 Xi'an 710032,China;State Key Laboratory of Military Stomatology&National Clinical Research Center for Oral Diseases&Shaanxi Key Laboratory of Stomatology,Department of Operative Dentistry and Endodontics,School of Stomatology,The Fourth Military Medical University,710032 Xi'an 710032,China;School of Aeronautics,Northwestern Polytechnical University,Xi'an)
Abstract:Objective:To establish and analyze the model of the digital framework of removable partial denture(RPD).Methods:The framework for maxillary Kennedy Class II defect was built by 3Shape Dental System software.The stress of the framework and its effect on abutment,mucosa and alveolar ridge was analyzed by Abaqus/CAE.Results:The accuracy of the digital model was high,and the structure of the framework was complete with good suitability.The finite element model based on digital framework had high similarity.The stress was concentrated on the small junction of the framework,and its distal end sank.The stress of the abutment on the gap side was higher than that of the contralateral abutment,and the high stress area appeared in the distal edentulous area.The results of finite element analysis reflected the force and motion of the framework in the mouth.Conclusion:The analysis and optimization of digital framework can improve the reliability of the design and manufacture of RPD framework.
Keywords:Digitization  Removable partial denture  Framework  Finite element analysis  3D printing
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号