婴幼儿胸部DR摄影距离对体表入射剂量与图像质量的影响
引用本文:孔祥闯,夏忠心,余建明. 婴幼儿胸部DR摄影距离对体表入射剂量与图像质量的影响[J]. 中华放射医学与防护杂志, 2011, 31(6): 719-721. DOI: 10.3760/cma.j.issn.0254-5098.2011.06.027
作者姓名:孔祥闯  夏忠心  余建明
作者单位:1. 华中科技大学同济医学院附属协和医院放射科, 武汉,430022
2. 孝感市第一人民医院
摘    要:目的 探讨胸部数字化X线摄影源像距(SID)对婴幼儿体表入射剂量(ESD)与图像质量的影响.方法 先进行仿真胸部体模实验性曝光,采用同一管电压(60 kVp)和不同SID(150 ~80 cm,10 cm为一组,共8组)进行曝光组合,记录每次曝光的毫安秒、ESD.选取试验中ESD相对剂量适中和较低的两组(110和90 ...

关 键 词:婴幼儿  数字化X线摄影  源像距( SID)  体表入射剂量  图像质量
收稿时间:2011-03-01

Effects of source to image receptor distance on image quality and entrance surface dose of chest digital radiography for infants
KONG Xiang-chuang,XIA Zhong-xin and YU Jian-ming. Effects of source to image receptor distance on image quality and entrance surface dose of chest digital radiography for infants[J]. Chinese Journal of Radiological Medicine and Protection, 2011, 31(6): 719-721. DOI: 10.3760/cma.j.issn.0254-5098.2011.06.027
Authors:KONG Xiang-chuang  XIA Zhong-xin  YU Jian-ming
Affiliation:Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 432100, China
Abstract:Objective To investigate the effects of source to image receptor distance (SID) on the image quality and entrance surface dose (ESD) in the chest digital radiography (DR) for infants.Methods Anthropomorphic chest phantoms were exposed to 60 kVp and different values of SID ( 150 -80 cm with the interval of 10 cm,totally 8 groups) so as to record the values of mAs and ESD.The SID values of 110 cm and 90 cm with the moderate and low ESD values were selected for clinical test.Forty-two hospitalized infants,aged 12 months (8 months to 2 years) underwent chest DR with the SID of 110 cm before admission and 90 cm before discharge respectively.The values of ESD were recorded and compared.Three experienced experts assessed the quality of 84 pieces of images.Results The values of mAs and ESD decreased gradually along with the decrease of the SID from 150 cm to 80 cm.All the 84 images from the 42 infants met the demands for diagnosis.There was no significant difference in the score of image quality of the group with the SID of 110 cm (4.4±0.3) and 90 cm(4.2±0.4) (t=0.453,P>0.05).The value of ESD of the group with the SID of 90 cm was significantly lower than that of the group of SID of 110 cm by 0.003 4 mGy ( t =12.001,P < 0.05 ).Conclusions The image quality of chest DR could meet the demands for diagnosis in spite of the value of SID,however,the SID value in chest DR significantly might influence the ESD.The SID value of 90 cm shoud be recommended in chest DR for infants.
Keywords:Infants  Digital radiography  Source to image receptor distance(SID)  Entrance surface dose (ESD)  Image quality