首页 | 本学科首页   官方微博 | 高级检索  
     


Clinical outcomes of second- versus first-generation drug-eluting stents in patients with acute myocardial infarction: a meta-analysis of randomized controlled trials
Authors:Guodong Wu  Guoqiang Sun  Ruihong Zhao  Mingli Sun
Affiliation:1.Department of Cardiology, First Hospital of Jilin University, Changchun, China;2.Department of Endoscopy and Gastroenterology, First Hospital of Jilin University, Changchun, China;3.Emergency Department, First Hospital of Jilin University, Changchun, China
Abstract:

Introduction

It remains unclear whether the clinical outcomes of patients with acute myocardial infarction (AMI) receiving second- and first-generation drug-eluting stents (DES) are identical. The study aimed to investigate the differences in clinical utility between the two generations of DES in these specific subjects by a meta-analysis.

Material and methods

We systemically searched PubMed and EMBASE databases and the Cochrane Library up until January 2013. Randomized trials, which compared clinical outcomes of second-generation DES (everolimus- (EES) or zotarolimus-eluting stents (ZES)) with first-generation DES (sirolimus- or paclitaxel-eluting stents) in patients with AMI were included.

Results

Five trials with 1720 AMI subjects were included in the meta-analysis. Pooled analysis demonstrated a trend toward lower incidence of stent thrombosis with the second-generation DES relative to the first-generation one (risk ratio (RR), 0.53; 95% confidence intervals (CI): 0.25–1.13; p = 0.10). However, the second-generation DES did not offer a significant advantage over the first-generation DES in reducing the incidence of target lesion revascularization (TLR) (RR = 1.73; 95% CI: 0.83–3.64; p = 0.15), major adverse cardiac events (MACEs) (RR = 0.97; p = 0.90), or all-cause death (RR = 1.00; p = 1.0). In addition, in elderly patients the second-generation DES seemed to reduce the occurrence of MACEs (RR = 0.65; p = 0.10) and stent thrombosis (RR = 0.40; p = 0.08), and the second-generation EES showed a potential benefit in lowering the MACE rate (RR = 0.55; p = 0.06).

Conclusions

The second-generation DES appeared to lower the risk of stent thrombosis in AMI patients. There might be a lower incidence of MACEs associated with the second-generation EES.
Keywords:acute myocardial infarction   second-generation drug-eluting stents   meta-analysis