首页 | 本学科首页   官方微博 | 高级检索  
     


Radiographic and Clinical Outcomes of Modular Tapered Fluted Stems for Femoral Revision for Paprosky III and IV Femoral Defects or Vancouver B2 and B3 Femoral Fractures
Affiliation:2. Department of Orthopedics, Kepler University Hospital, Linz, Austria
Abstract:BackgroundExtensive femoral bone loss poses a challenge in revision total hip arthroplasty (rTHA). Many techniques have been developed to address this problem including fully porous cylindrical stems, impaction bone grafting, and cementation of long stems, which have had varied success. Modular tapered fluted femoral stems (MTFS) show favorable results. We sought to determine the minimum 2-year radiographic and clinical performance of MTFS in rTHA in a population with extensive proximal femoral bone loss.MethodsOur clinical database was queried retrospectively for all patients who underwent rTHA with an MTFS. We included patients with Paprosky 3 and 4 femoral bone loss and patients with Vancouver B2 and B3 periprosthetic femur fractures. Patients without 2-year follow-up were invited to return to clinic for X-ray evaluation and to complete clinical questionnaires. We assessed distance of stem subsidence and presence of stem fixation on final X-ray. We recorded all-cause revision and survival of the stem at final follow-up.ResultsOne hundred twenty-nine patients were available for follow-up. Average follow-up time was 3.75 years. One hundred twenty-two stems (95%) remained in place at final follow-up. Median subsidence was 1.4 mm (range 0-21). All-cause revision rate was 16.3% (21 patients). Of the hips revised, 10 were for instability, 6 for infection, 1 for aseptic loosening, and 1 for periprosthetic femur fracture. Three were revised for other reasons. The stem was revised in 7 patients (5.4%), and the most common reason for stem revision was infection (5 patients). The other 2 stems were revised for aseptic loosening in a Paprosky 4 femur and periprosthetic femur fracture. Survival of tapered modular fluted stems with aseptic failure as an endpoint was 98.4%. The mean Hip disability and Osteoarthritis Outcome Score, Joint Replacement score at final follow-up was 73, and mean Veterans Rand 12 item health survey physical and mental scores were 32.8 and 52.2, respectively.ConclusionIn patients with Paprosky 3, 4 femoral defects or Vancouver type B2, B3 fractures, modular tapered fluted stems for femoral revision show excellent outcomes at minimum 2-year follow-up.
Keywords:bone loss  revision total hip arthroplasty  modular tapered fluted stem  femoral revision  outcomes
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号