Plasma Fibrinogen Performs Better Than Plasma d-Dimer and Fibrin Degradation Product in the Diagnosis of Periprosthetic Joint Infection and Determination of Reimplantation Timing
Affiliation:1. Department of Orthopaedic Surgery, Holy Cross Hospital, Orthopaedic Research Institute, Fort Lauderdale, FL;2. Department of Orthopaedic Surgery, Albany Medical Center, Albany, NY;3. Department of Orthopaedic Surgery, Northwell Health, Lenox Hill Hospital, New York, NY;4. Department of Orthopaedic Surgery, Cleveland Clinic Hospital, Cleveland, OH;1. Ortopedia-Traumatologia e Chirurgia protesica e dei reimpianti d''anca e di ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy;2. Professor of Orthopedics and Traumatology, University of Messina, Italy
Abstract:BackgroundThe accurate and timely diagnosis of periprosthetic joint infection (PJI) is challenging, and no single biomarker can definitively confirm infection before revision arthroplasty. The coagulation cascade has been linked closely to infection. This study was performed to determine the value of plasma d-dimer, plasma fibrinogen, and plasma fibrin degradation product (FDP) for the diagnosis of PJI and timing of reimplantation.MethodsWe retrospectively enrolled 136 patients who underwent revision surgery from January 2008 to December 2019. They were assigned to 3 groups: aseptic failure (group A), PJI (group B), and reimplantation (group C). Receiver operating characteristic curves were constructed to estimate the value of plasma fibrinogen, plasma d-dimer, plasma FDP, erythrocyte sedimentation rate (ESR), and serum C-reactive protein (CRP) for PJI diagnosis and reimplantation timing.ResultsAll biomarker levels were significantly higher in group B than in group A (P < .05), and plasma fibrinogen, CRP, and ESR values were significantly higher in group B than in group C (all P < .05). The receiver operating characteristic curves showed that the areas under the curve of plasma fibrinogen, plasma d-dimer, plasma FDP, CRP, and ESR were 0.848, 0.914, 0.728, 0.737, and 0.868, respectively, and the threshold values for plasma fibrinogen, plasma d-dimer, and plasma FDP were 3.61 g/L, 0.41 mg/L, and 3.55 mg/L, respectively.ConclusionPlasma fibrinogen exhibits good value for the diagnosis of PJI and can be an indicator of residual infection before reimplantation in 2-stage arthroplasty. Plasma d-dimer and FDP are of limited value for PJI diagnosis and cannot be used to determine the timing of reimplantation.
Keywords:periprosthetic joint infection  diagnostic value  reimplantation  fibrin degradation product  fibrinogen
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号