摘    要:为了解手术过程中洁净手术室空气细菌污染状况及其影响因素。采用自然沉降法对10个洁净手术室空气进行采样检测。结果,Ⅲ级洁净手术室手术区空气中自然菌总数为5.42 cfu/30m in/平板,周边区空气中菌数为3.42 cfu/30m in/平板。手术区空气中菌数显著高于周边区(P<0.01),手术过程中沉降菌浓度变化不明显,超标率达21%。采取提前作好准备、减少人员流动等干预措施后,沉降菌浓度明显降低,合格率100%。手术室空气中细菌多数为葡萄球菌属,包括金黄色葡萄球菌(有一定数量的耐甲氧西林金黄色葡萄球菌)以及微球菌属等。结论,Ⅲ级洁净手术室在手术过程中空气细菌污染严重,手术人员的活动及人数是影响沉降菌浓度变化的主要因素。

关 键 词:洁净手术室  空气中菌数  自然沉降法
文章编号:1001-7658(2006)03-0157-02
收稿时间:2005-08-18
修稿时间:2005年8月18日

MONITORING OF BACTERIA IN AIR OF THE CLEAN OPERATING ROOM IN THE COURSE OF OPERATION AND ANALYSIS OF INFLUENCING FACTORS
GONG Qing-yue,JIAO Ling,ZHANG Xue-xiang.MONITORING OF BACTERIA IN AIR OF THE CLEAN OPERATING ROOM IN THE COURSE OF OPERATION AND ANALYSIS OF INFLUENCING FACTORS[J].Chinese Journal of Disinfection,2006,23(2):157-158.
Authors:GONG Qing-yue  JIAO Ling  ZHANG Xue-xiang
Institution:Affiliated Yantai Yuhuangdin Hospital, Qingdao University Medical School, Yantai 264000, China
Abstract:In order to know the status of bacterial contamination of air of clean operating room in the course of operation and its influencing factors,natural sedimentation method was used to sample the air of 10 clean operating rooms.Results: The total natural bacterial count in air of operation area of grade-3 clean operating room was 5.42 cfu/30 min per plate,and the bacterial count in air of periphery of operation area was 3.42 cfu/30 min per plate.The bacterial count in air of operation area was significantly higher than that of the peripheral area(P<0.01).The concentration of bacteria descending in the course of operation did not change significantly,with rate of exceeding allowable limit attaining 21%.After taking interfering measures such as preparedness in advance and reducing traffic in the operation area,the concentration of descending bacteria decreased obviously,attaining 100% eligible rate.The bacteria in air of operating rooms were mostly Staphlococcus,including Staphylococcus aureus (with a certain amount of(meticillin-resistant) S.aureus) and Micrococcus.Conclusions: The air of grade-3 clean operating rooms is heavily contaminated by bacteria in the course of operation.Activity and number of operating staff are the main factors influencing the change in concentration of descending bacteria.