Effect of thickness and surface modifications on flexural strength of monolithic zirconia
Authors:Fusun Ozer  Andrew Naden  Volkan Turp  Francis Mante  Deniz Sen  Markus B. Blatz
Affiliation:1. Associate Professor, University of Pennsylvania School of Dental Medicine, Department of Preventive and Restorative Sciences, Philadelphia, Pa;2. Predoctoral student, University of Pennsylvania School of Dental Medicine, Department of Preventive and Restorative Sciences, Philadelphia, Pa;3. Associate Professor, Istanbul University Faculty of Dentistry, Department of Prosthodontics, Istanbul, Turkey;4. Associate Professor, University of Pennsylvania School of Dental Medicine, Department of Preventive and Restorative Sciences, Philadelphia, Pa;5. Professor, Istanbul University, Faculty of Dentistry, Department of Prosthetic Dentistry, Istanbul, Turkey;6. Professor and Chair, Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, Philadelphia, Pa
Abstract:

Statement of problem

A recommended minimum thickness for monolithic zirconia restorations has not been reported. Assessing a proper thickness that has the necessary load-bearing capacity but also conserves dental hard tissues is essential.

Purpose

The purpose of this in vitro study was to evaluate the effect of thickness and surface modifications on monolithic zirconia after simulated masticatory stresses.

Material and methods

Monolithic zirconia disks (10 mm in diameter) were fabricated with 1.3 mm and 0.8 mm thicknesses. For each thickness, 21 disks were fabricated. The specimens of each group were further divided into 3 subgroups (n=7) according to the surface treatments applied: untreated (control), airborne-particle abrasion with 50-μm Al2O3 particles at a pressure of 400 kPa at 10 mm, and grinding with a diamond rotary instrument followed by polishing. The biaxial flexure strength was determined by using a piston-on-3-balls technique in a universal testing machine. Flexural loading was applied with a 1.4-mm diameter steel cylinder, centered on the disk, at a crosshead speed of 0.5 mm/min until fracture occurred. X-ray diffraction (XRD) and scanning electron microscopy (SEM) analyses were performed. The data were statistically analyzed with 2-way ANOVA, Tamhane T2, 1-way ANOVA, and Student t tests (α=.05).

Results

The 1.3-mm specimens had significantly higher flexural strength than the 0.8-mm specimens (P<.05). Airborne-particle abrasion significantly increased the flexural strength (P<.05). Grinding and polishing did not affect the flexural strength of the specimens (P>.05).

Conclusions

The mean flexural strength of 0.8-mm and 1.3-mm thick monolithic zirconia was greater than reported masticatory forces. Airborne-particle abrasion increased the flexural strength of monolithic zirconia. Grinding did not affect flexural strength if subsequently polished.
Keywords:Corresponding author: Dr Volkan Turp   Istanbul University Faculty of Dentistry   Department of Prosthodontics   34093 Fatih   Istanbul   TURKEY