首页 | 本学科首页   官方微博 | 高级检索  
     

非对比剂增强MRA在肾静脉血管成像中的应用价值
引用本文:李晓娟,陈晓,孟晓岩,汤浩,李浩杰,胡道予. 非对比剂增强MRA在肾静脉血管成像中的应用价值[J]. 放射学实践, 2017, 32(1): 52-56. DOI: 10.13609/j.cnki.1000-0313.2017.01.011
作者姓名:李晓娟  陈晓  孟晓岩  汤浩  李浩杰  胡道予
作者单位:华中科技大学同济医学院附属同济医院放射科,武汉,430030
基金项目:国家自然科学基金(81371524)及国家自然科学青年基金(81501447)
摘    要:目的:评估多反转脉冲空间标记(SLEEK)非对比剂增强磁共振血管成像(NCE-MRA)技术对显示肾脏肿瘤患者肾静脉的可行性及静脉内瘤栓的诊断效能.方法:纳入行手术治疗的肾脏肿瘤患者共32例,所有患者均知情同意,32例患者均行SLEEK序列扫描,获取双肾静脉及下腔静脉原始图像.对70支肾静脉及32支下腔静脉的原始图像、最大密度投影(MIP)图像、多平面重建图像进行评估,包括图像质量、瘤栓显示,以病理结果为金标准,评估SLEEK对瘤栓显示的准确度、敏感度及特异度.结果:非肿瘤侧肾静脉(34支)图像质量评分均在2分及以上,肿瘤侧97.2%(35/36)的肾静脉图像质量评分在2分及以上.1支肿瘤侧肾静脉显示差,不足以用于诊断,对余下肿瘤侧肾静脉及下腔静脉以病理为金标准进行评估,SLEEK显示16支肾静脉有瘤栓,14支下腔静脉有瘤栓,病理均证实;SLEEK显示无瘤栓的静脉病理中亦未发现瘤栓.SLLEK诊断准确度、敏感度及特异度均为100%.两位医师评分及诊断的一致性较好,Kappa值均>0.75.结论:SLEEK可准确诊断肾脏肿瘤患者静脉内瘤栓存在情况,并可多角度观察瘤栓范围,从而指导临床手术方案的选择.

关 键 词:肾肿瘤  静脉瘤栓  多反转脉冲空间标记  磁共振成像

Application of non contrast enhanced MRA in renal vein imaging
Abstract:Objective:To evaluate the diagnostic value of non contrast enhanced MRA (NCE MRA) using spatial labeling with multiple inversion pulses (SLEEK) in assessing intravenous tumor embolus in patients with renal tumor.Methods:Informed consents were obtained from 32 patients who underwent renal tumor surgery.All patients received SLEEK MR examination,anatomic images of bilateral renal veins and inferior vena cava were obtained.Original image of 70 renal veins and 32 inferior vena cava were assessed,The image quality,display of intravenous tumor embolus were evaluated by MIP and MPR techniques.Taking pathology as gold standard,the diagnostic accuracy,sensitivity and specificity of SLEEK in displaying intravenous tumor embolus were evaluated.Results:Of 34 renal veins on intact side,the image quality score was 2 points and above.Of the renal vein on tumor side,97.2% (35/36) were scored as 2 points and above.The image of one renal vein on tumor side was not clear enough for diagnosis.Among the remaining renal veins of tumor side and inferior vena cava,SLEEK detected 16 renal venous tumor embolus and 14 inferior vena cava tumor embolus,which were all confirmed by pathology.The diagnostic accuracy,sensitivity and specificity of SLEEK in detecting tumor embolus were 100% for all.The scores evaluated by two radiologists showed good consistency with Kappa values >0.75.Conclusion:SLEEK is accurate in the diagnosis of intravenous tumor embolus and can display tumor embolus in multiple views,which is be helpful for the selection of surgical treatment planning.
Keywords:Kidney neoplasms  Intravenous tumor thrombus  Spatial labeling with multiple inversion pulses  Magnetic resonance imaging
本文献已被 万方数据 等数据库收录!
点击此处可从《放射学实践》浏览原始摘要信息
点击此处可从《放射学实践》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号