首页 | 本学科首页   官方微博 | 高级检索  
     

应用Sonoclot体外监测低分子肝素及磺达肝癸钠的抗凝作用
引用本文:徐晶晶,张梅,周欣,王飞,姜铁民,刘千萍,潘坤颖. 应用Sonoclot体外监测低分子肝素及磺达肝癸钠的抗凝作用[J]. 天津医科大学学报, 2012, 18(2): 217-220
作者姓名:徐晶晶  张梅  周欣  王飞  姜铁民  刘千萍  潘坤颖
作者单位:1. 天津医科大学研究生院,天津300070;武警后勤学院附属医院心内科,天津300162
2. 武警后勤学院附属医院心内科,天津,300162
摘    要:目的:探讨Sonoclot凝血仪在分析监测凝血与血小板功能的临床价值。方法:在gb试剂杯加入不同浓度的低分子肝素钠(0~1.6 IU/mL抗Xa因子)、低分子肝素钙(0~1.64 IU/mL抗Xa因子)、磺达肝癸钠(0~1.52μg/mL),抽取10例健康志愿者血样,并加入有药物的试剂杯中,用Sonoclot凝血仪进行检测,检测指标分别包括激活凝血时间(ACT)、凝血速率(CR)和血小板功能(PF)。结果:(1)3种抗凝药物随着浓度的增加,其ACT值逐渐增加,CR值逐渐下降,PF值逐渐下降。(2)对于同一治疗量的3种抗凝药物,低分子肝素钠(1.2 IU/mL抗Xa因子)与低分子肝素钙(1.23 IU/mL抗Xa因子),其ACT、CR、PF 3个参数的比较,P>0.05,无统计学差异。磺达肝癸钠(0.77μg/mL)与低分子肝素钠(1.2 IU/mL抗Xa因子)和低分子肝素钙(1.23 IU/mL抗Xa因子)相比,其ACT、CR、PF 3个参数均有差异性,均P<0.01。结论:Sonoclot凝血仪可以快速检测低分子肝素及磺达肝癸钠的抗凝效果以及对于血小板功能的影响,可以对临床给药剂量和个体化治疗做出指导。

关 键 词:Sonoclot凝血仪  凝血功能  血小板功能  低分子肝素钠  磺达肝癸钠  低分子肝素钙

Anticoagulation effects of low molecular heparin and fondaparinux in vitro by the Sonoclot analyzer
XU Jing-jing , ZHANG Mei , ZHOU Xin , WANG Fei , JIANG Tie-min , LIU Qian-ping , PAN Kun-ying. Anticoagulation effects of low molecular heparin and fondaparinux in vitro by the Sonoclot analyzer[J]. Journal of Tianjin Medical University, 2012, 18(2): 217-220
Authors:XU Jing-jing    ZHANG Mei    ZHOU Xin    WANG Fei    JIANG Tie-min    LIU Qian-ping    PAN Kun-ying
Affiliation:1.Graduate School,Tianjin Medical University,Tianjin 300070,China;2.Department of Cardiology,The Affiliated Hospital of College of The Armed Police,Tianjin 300162,China)
Abstract:Objective: To examine the Sonoclot analyzer’s capability and in monitoring the blood coagulation and platelet function in vitro and evaluate its practical clinical significance.Methods: The blood samples were taken from 10 healthy volunteers after 1 h break.The samples were added into the gb cups in which different concentrations of low-molecular-weight heparin sodium(LHWHs)(0~1.6 IU/mL anti-Xa factor),low-molecular-weight heparin calcium(LHWHc)(0~1.64 IU/mL anti-Xa factor) and fondaparinux(0 ~1.52 μg/mL) were added respectively in advance.The ACT,CR and PF were tested by the Sonoclot anaylzer.Results:(1) ACT in three groups increased significantly(P<0.01) with the increasing concentration of LMWHs,LMWHc and fondaparinux.CR and PF decreased significantly(P<0.01) with the increasing concentration of LMWHs,LMWHc and fondaparinux.(2)There was no significant difference between the LMWHs(1.2 IU/mL anti-Xa factor) and LMWHc(1.23 IU/mL anti-Xa factor) group1in terms of the ACT and PF(P>0.05) in the concentration(1.2 IU/mL LMWHs and 1.23 IU/mL LMWHc).There was significant difference between fondaparinux(0.77 μg/mL) LMWHs(1.2 IU/mL anti-Xa factor) and LMWHc(1.23 IU/mL anti-Xa factor) with respect to ACT,CR and PF(P<0.01).Conclusion: Sonoclot analyzer can quickly detect low-molecular-weight heparin and fondaparinux anticoagulation effect and the platelet function,it can be reliable in providing guidance for clinical dose and individual treatment.
Keywords:Sonoclot coagulation analyzer  coagulation  platelet function  low-molecular-weight heparin sodium  fondaparinux  low-molecular-weight heparin calcium
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号