52例人工生物瓣膜临床应用分析
引用本文:李峰,胡建国,尹邦良,杨进福,唐滔,高华. 52例人工生物瓣膜临床应用分析[J]. 中南大学学报(医学版), 2008, 33(3): 257-261
作者姓名:李峰  胡建国  尹邦良  杨进福  唐滔  高华
作者单位:中南大学湘雅二医院胸心外科,长沙,410011;湖南省心血管病研究所,长沙,410011;中南大学湘雅二医院胸心外科,长沙,410011;湖南省心血管病研究所,长沙,410011;中南大学湘雅二医院胸心外科,长沙,410011;湖南省心血管病研究所,长沙,410011;中南大学湘雅二医院胸心外科,长沙,410011;湖南省心血管病研究所,长沙,410011;中南大学湘雅二医院胸心外科,长沙,410011;湖南省心血管病研究所,长沙,410011;中南大学湘雅二医院胸心外科,长沙,410011;湖南省心血管病研究所,长沙,410011
基金项目:卫生部临床学科重点项目(2001-321)
摘    要:目的:总结分析异种心脏生物瓣膜置换的临床应用结果,评价生物瓣膜在瓣膜外科中的应用效果及趋势.方法:回顾性分析2002年6月~2006年6月,在我科接受异种生物瓣膜置换术的患者52例,年龄13~73(52.4±14.0)岁,手术置入生物瓣膜53枚,合用机械瓣膜8枚;同期行双向Clenn分流术1例,B型预激旁路切除术1例,冠脉搭桥术5例;房/室间隔缺损修补4例.结果:术后早期(30 d内)死于多器官功能衰竭1例.平均随访25个月,随访率96%.随访病例生存良好,心功能Ⅰ级41例、Ⅱ级9例、Ⅲ级1例.心脏彩超示瓣膜功能良好,无明显衰败迹象.结论:人工生物瓣膜置换疗效确切,并发症少,在保证手术技术的情况下.近期效果较好.

关 键 词:瓣膜置换术  生物瓣膜  临床应用
文章编号:1672-7347(2008)03-0257-05
收稿时间:2007-04-03
修稿时间:2007-04-03

Retrospective study on clinical application of biovalves in 52 cases
LI Feng,HU Jian-guo,YIN Bang-liang,YANG Jin-fu,TANG Tao,GAO Hua. Retrospective study on clinical application of biovalves in 52 cases[J]. Journal of Central South University. Medical sciences, 2008, 33(3): 257-261
Authors:LI Feng  HU Jian-guo  YIN Bang-liang  YANG Jin-fu  TANG Tao  GAO Hua
Affiliation:1.Department of Cardiothoracic Surgery, Second Xiangya Hospital, Central South University, Changsha 410011;
2.Hunan Cardiovascular Institute, Changsha 410011, China
Abstract:OBJECTIVE: To summarize the clinical application of bioprosthetic valve replacement. METHODS: Fifty two patients, aged 13-73(52.4+/-14.0) years, underwent cardiac valve replacement with biovalves from June 2002 to June 2006 in our hospital. Fifty three tissue valve replacements combined with 8 mechanical valve replacements were performed. Other procedures were also carried out if appropriate, including bidirectional Glenn shunt in 1 patient with double outlet of right ventricle and pulmonary artery stenosis; interruption of accessory pathway in 1 patient with Wolff-Parkinson-White syndrome; coronary artery bypass graft in 5 with severe coronary artery disease; and atrial or ventricular repair in 4 with congenital septum defects. RESULTS: One patient died in hospital due to multiple organ failure. The hospital mortality rate was 1.9%. The mean follow-up was 25 months. Two patients lost follow-up and the follow-up rate was 96%. Forty one patients returned to NYHA class I, 9 to class II, and 1 to class III. Echocardiography showed the implanted bioprosthesis functioned well without stenosis or regurgitation. There was no structural deterioration with freedom from thromboembolism and anticoagulant hemorrhage in all patients. CONCLUSION: The efficacy of biovalves in heart valve replacement is satisfactory.
Keywords:cardiac valve replacement  biovalve  clinical application