首页 | 本学科首页   官方微博 | 高级检索  
     


Carotid artery Dacron patch graft angioplasty: a ten-year experience
Authors:G A Schultz  M Zammit  L R Sauvage  M P Spencer  T E Kowalsky  S G Goff  J C Smith
Affiliation:Bob Hope International Heart Research Institute, Providence Medical Center, Seattle, WA 98122.
Abstract:Of 394 carotid endarterectomies performed during a 10-year period, 36 (9%) included Dacron patch graft angioplasties. Patch graft angioplasties were used selectively in patients because they had undergone previous carotid endarterectomy or had small-caliber vessels. There were no postoperative infections, occlusions, emboli, stroke, or pseudoaneurysms. In addition, no clinically detectable recurrent stenoses developed in this high-risk group of patients. Twenty-four of the 27 patients available for follow-up were screened for asymptomatic stenoses with spectral analysis and B-mode imaging; there was no sign of hemodynamically significant recurrent stenosis in this group. These encouraging results support the continued selective use of Dacron patch graft angioplasty in carotid surgery.
Keywords:
本文献已被 ScienceDirect 等数据库收录!