首页 | 本学科首页   官方微博 | 高级检索  
检索        


Neonatal reference values for ionized calcium, phosphate and magnesium. Selection of reference population by optimality criteria
Authors:N Nelson  O Finnstr?m  L Larsson
Abstract:Thirty-one full-term newborn babies were investigated in order to establish reference values for ionized calcium. Only children fulfilling certain optimality criteria (with best possible maternal and infant conditions and uncomplicated pregnancy and delivery) were included. All infants were breast fed. Capillary blood for analysis of ionized calcium was collected by heel puncture on day 1 (6-36 h post partum, p.p.), day 3 (60-84 h p.p.) and day 5 (108-132 h p.p.). Ionized calcium was measured with a semi-automatic electrode system ICA 1 (Radiometer A/S, Copenhagen, Denmark). The reference ranges (mean +/- 2 SD) for days 1, 3 and 5 were 1.05-1.37, 1.10-1.42 and 1.20-1.48 mmol/l, respectively. The mean ionized calcium concentration on day 1 was significantly lower than on days 3 and 5. Reference values are also given for total calcium, magnesium and phosphate. We emphasize that it is impossible to calculate ionized calcium from total calcium or vice versa.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号