首页 | 本学科首页   官方微博 | 高级检索  
检索        


Relation of the Static Compliance Curve and Positive End-expiratory Pressure to Oxygenation during One-lung Ventilation
Authors:Slinger  Peter D MD  FRCPC; Kruger  Marelise MBChB  FRCA&#x;; McRae  Karen MD  FRCPC&#x;; Winton  Timothy MD  FRCSC
Institution:Slinger, Peter D. M.D., F.R.C.P.C.*; Kruger, Marelise M.B.Ch.B., F.R.C.A.?; McRae, Karen M.D., F.R.C.P.C.?; Winton, Timothy M.D., F.R.C.S.C.§
Abstract:Background : Positive end-expiratory pressure (PEEP) is commonly applied to the ventilated lung to try to improve oxygenation during one-lung ventilation but is an unreliable therapy and occasionally causes arterial oxygen partial pressure (Pao2) to decrease further. The current study examined whether the effects of PEEP on oxygenation depend on the static compliance curve of the lung to which it is applied.

Methods : Forty-two adults undergoing thoracic surgery were studied during stable, open-chest, one-lung ventilation. Arterial blood gasses were measured during two-lung ventilation and one-lung ventilation before, during, and after the application of 5 cm H2O PEEP to the ventilated lung. The plateau end-expiratory pressure and static compliance curve of the ventilated lung were measured with and without applied PEEP, and the lower inflection point was determined from the compliance curve.

Results : Mean (+/- SD) Pao2 values, with a fraction of inspired oxygen of 1.0, were not different during one-lung ventilation before (192 +/- 91 mmHg), during (190 +/- 90), or after ( 205 +/- 79) the addition of 5 cm H2O PEEP. The mean plateau end-expiratory pressure increased from 4.2 to 6.8 cm H2O with the application of 5 cm H2O PEEP and decreased to 4.5 cm H2O when 5 cm H2O PEEP was removed. Six patients showed a clinically useful (> 20%) increase in Pao2 with 5 cm H2O PEEP, and nine patients had a greater than 20% decrease in Pao2. The change in Pao2 with the application of 5 cm H2O PEEP correlated in an inverse fashion with the change in the gradient between the end-expiratory pressure and the pressure at the lower inflection point (r = 0.76). The subgroup of patients with a Pao2 during two-lung ventilation that was less than the mean (365 mmHg) and an end-expiratory pressure during one-lung ventilation without applied PEEP less than the mean were more likely to have an increase in Pao2 when 5 cm H2O PEEP was applied.

Keywords:
点击此处可从《The Journal of the American Society of Anesthesiologists》浏览原始摘要信息
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号