首页 | 本学科首页   官方微博 | 高级检索  
     

基于2D/3D配准技术评估两种可调式颈托对椎间孔形态的影响
引用本文:曾意君,张鑫涛,叶强,李鉴轶,李文睿. 基于2D/3D配准技术评估两种可调式颈托对椎间孔形态的影响[J]. 中国临床解剖学杂志, 2018, 36(3): 325-328. DOI: 10.13418/j.issn.1001-165x.2018.03.018
作者姓名:曾意君  张鑫涛  叶强  李鉴轶  李文睿
作者单位:1.南方医科大学人体解剖学教研室 广东省医学生物力学重点实验室, 广州 510515;
2.南方医科大学第三附属医院影像科, 广州 510630
基金项目:广东省省级科技计划项目(2012B091100314,2014A020212200,2015A040404022,2015B010125006,2015B010125005)
摘    要:目的 基于2D/3D配准技术评估可调式颈托一代与二代对椎间孔形态的影响并进行对比,从而探讨哪种颈托可以更好地为颈椎病患者提供牵引治疗。 方法 利用2D/3D配准技术采集C2/3、C3/4、C4/5、C5/6双侧椎间孔面积等数据,计算不同角度椎间孔面积差值及面积增长率。统计对比颈托一代与二代不同角度椎间孔面积差值及面积增长率。 结果 通过对比,第二代颈托的牵引效果在颈椎大部分位置上统计学结果是显著的,差异有统计学意义(P<0.05),尤其是C5/6节段在4个牵引角度上都是显著的。 结论 第二代颈托对于扩大椎间孔面积效果优于第一代颈托,能更有效地对颈椎病患者进行牵引治疗。

关 键 词:2D/3D配准技术   可调式颈托   椎间孔形态学参数  
收稿时间:2017-12-24

Evaluation of the effect of the two kinds of the adjustable neck bracket on the morphological parameters of intervertebral foramen based on 2D/3D registration technique
ZENG Yi-jun,ZHANG Xin-tao,YE Qiang,LI Jian-yi,LI Wen-rui. Evaluation of the effect of the two kinds of the adjustable neck bracket on the morphological parameters of intervertebral foramen based on 2D/3D registration technique[J]. Chinese Journal of Clinical Anatomy, 2018, 36(3): 325-328. DOI: 10.13418/j.issn.1001-165x.2018.03.018
Authors:ZENG Yi-jun  ZHANG Xin-tao  YE Qiang  LI Jian-yi  LI Wen-rui
Affiliation:1.Department of Anatomy, Guangdong Provincial Key Laboratory of Medical Biomechanics, Southern Medical University, Guangzhou 510515,China;2.Department of Radiology,The Third Affiliated Hospital,Southern Medical University, Guangzhou 510630,China
Abstract:Objective To investigate the effect of the two kinds of the adjustable neck bracket on the morphological parameters of the intervertebral foramen based on 2D/3D registration technique. And compare the two to discuss which kind of neck bracket can better provide traction treatment for patients with cervical spondylosis. Methods The 2D/3D registration technique was used to measure the bilateral intervertebral foramen area of C2/3, C3/4, C4/5 and C5/6. The intervertebral foramen area growth rates of different angles were calculated. The d-value of intervertebral foramen area and area growth rate of different angles between the first and the second generation of the neck bracket were statistically compared. Results By contrast, the effect of the second generation of the adjustable neck bracket was statistically significant in most cervical vertebrae(P<0.05). In particular, the C5/6 segment was significant at 4 angles. Conclusion The effect of the second generation of the neck bracket in the enlargement of the area of the intervertebral foramen is better than that of the first generation. And the traction therapy for patients with cervical spondylosis is more effectively.
Keywords:2D/3D registration technique    ,Adjustable neck bracket    ,Morphological parameters of intervertebral foramen,
本文献已被 CNKI 等数据库收录!
点击此处可从《中国临床解剖学杂志》浏览原始摘要信息
点击此处可从《中国临床解剖学杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号