Concordance of skin prick test and serum-specific IgE to locally produced component-resolved diagnostics for cockroach allergy
Authors:Nitat Sookrung  Pichade Jotikaprasardhna  Chaweewan Bunnag  Wanpen Chaicumpa  Anchalee Tungtrongchitr
Institution:2. Center of Research Excellence on Therapeutic Proteins and Antibody Engineering, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand;3. Lerdsin Hospital, Silom, Bangrak, Bangkok, Thailand;4. Department of Oto-Rhino-Laryngology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand;5. Department of Parasitology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
Abstract:

Background

Diagnosis of Periplaneta americana (American cockroach, ACR) allergy is commonly performed based on clinical history and skin prick test (SPT) or specific serum IgE (sIgE) measurement. The concordance of the findings with the SPT and sIgE results has never been investigated.

Objective

To compare the results of SPT with commercial ACR-extract (C-ACE) and sIgE measurement, using commercial kit and in-house enzyme-linked immunosorbent assay (ELISA) to the locally produced ACR extract (L-ACE) and native Per a 1, Per a 5, Per a 7, and Per a 9.

Methods

Sera from 66 individuals clinically diagnosed with chronic allergic rhinitis were included; 46 were positive SPT to C-ACE, and 20 were negative. Specific serum IgE levels were established by using a commercial test kit (ImmunoCap) and an in-house IgE-ELISA

Results

The percentage the C-ACE SPT-positive cases that were positive by the ImmunoCap-sIgE was 32.6%, indicating low concordance of the 2 assays. With the in-house ELISA, Per a 9 gave the highest sensitivity (98.00%), positive predictive value (PPV; 95.74%), and negative predictive value (NPV; 94.74%) of the sIgE quantification. The correlation coefficients (R) of the L-ACE-SPT and sIgE to L-ACE, Per a 1, Per a 5, Per a 7, and Per a 9 and ImmunoCap sIgE were 0.133, 0.278, 0.419, 0.280, and 0.432, and 0.256, respectively.

Conclusion

Skin prick test and sIgE measurement using commercial reagents have low concordance. Data of this study showed that sIgE to the native Per a 9 should be considered as an adjunct to the clinical history in diagnosis of ACR sensitization/allergy, particularly when the SPT and the nasal challenge, which is the gold standard method, cannot be performed.