摘    要:目的探讨洁净手术室共用净化空调对手术间空气环境的影响.方法根据洁净手术室分级标准,选择20例外科手术在共用净化空调手术间其中一间施行手术,分别在施行手术的手术间和未施行手术的手术间分时段采样做空气细菌培养.结果施行手术手术间皮肤切开前15 min和术毕整理手术间时菌落数显著高于术前空调运行30 min(均P<0.01),且显著高于未施行手术手术间同时段(均P<0.01);未施行手术间各时段菌落数比较,差异无显著性意义(均P>0.05).结论共用净化空调不会对洁净手术间空气环境造成影响.

关 键 词:洁净手术室  净化空调  集落计数,微生物  空气

Effect of Sharing Cleaning Air-conditioners on Air Condition in Operating Room
NI Ledan,XU Jiangtao,ZHENG Shuzhi. Effect of Sharing Cleaning Air-conditioners on Air Condition in Operating Room[J]. Journal of Nursing Science, 2006, 21(10)
Authors:NI Ledan  XU Jiangtao  ZHENG Shuzhi
Abstract:Objective To investigate the effect of sharing cleaning air-conditioners on air hygiene in operating room. Met-hods Twenty surgical operations were done in one of operation room with shared cleaning air-conditioners. Air bacteria were collected and cultured at operation time and non-operation time. Results The colonies in the operating room 15 minutes before the skin incision and the colonies after the operation were significantly higher than those 30 minutes after the running of the air-conditioners (P<0.01 for all) and the colonies were higher than the corresponding periods of non-operation room (P<0.01 for all). The colonies in non-operating room were not significantly different at different times (P>0.05 for all). Conclusion The sharing of cleaning air-conditioners does not affect the air environment of clean operating room.
Keywords:clean operating room  cleaning air-conditioners  colony count   microbial  air