首页 | 本学科首页   官方微博 | 高级检索  
检索        


Sustained clinical safety and efficacy of a biodegradable‐polymer coated sirolimus‐eluting stent in “real‐world” practice: Three‐year outcomes of the CREATE (multi‐center registry of EXCEL biodegradable polymer drug eluting stents) study
Authors:Yaling Han MD  Quanmin Jing MD  Yi Li MD  Lixia Yang MD  Huiliang Liu MD  Xiaoming Shang MD  Tiemin Jiang MD  Zhanquan Li MD  Hua Zhang MD  Gaoliang Yan MBBS  The Multi‐Center Registry of EXCEL BiodegrAdable Polymer Drug EluTing Stents investigators
Institution:1. Department of Cardiology, Shenyang Northern Hospital, Shenyang, China;2. Department of Cardiology, Kunming General Hospital of Chengdu Military Region, Kunming, China;3. Department of Cardiology, General Hospital of Armed Police Forces, Beijing, China;4. Department of Cardiology, Tangshan Gongren Hospital, Tangshan, China;5. Affiliated Hospital of Chinese people's Armed Police Forces Medical College, Tianjin, China;6. Department of Cardiology, The People's Hospital of Liaoning Province, Shenyang, China;7. Department of Cardiology, Shanxi Provincial Corps Hospital of Chinese People's Armed Police Forces, Xi'an, China
Abstract:Background: The CREATE is a post‐marketing surveillance multicenter registry that demonstrated satisfactory angiographic and clinical (at 18 months) outcomes of a biodegradable polymer based sirolimus‐eluting stent (EXCEL, JW Medical System, Weihai, China) for the treatment of patients in routine clinical practice. Objectives: To evaluate the three‐year clinical safety and efficacy outcomes in patients enrolled in the CREATE study. Methods: A total of 2077 all comers have been enrolled in the CREATE study at 59 centers from four countries. Recommended antiplatelet regimen was clopidogrel and aspirin for six months followed by chronic aspirin therapy. The prespecified primary outcome was the rate of major adverse cardiac events (MACE) at 12, 18, and 36 months. Results: Clinical follow‐up was completed in 2025 (97.5%) patients at three years. The average duration of clopidogrel treatment was 199.8 ± 52.7 days and 80.5% of discharged patients discontinued clopidogrel at six months. The cumulative rate of MACE was 4.5% and the rate of stent thrombosis was 1.53% at three years. At six months to three years, prolonged clopidogrel therapy (>6 months) was not beneficial in reducing cumulative hazards of MACE (3.4% vs. 3.1%, log rank P = 0.725) or stent thrombosis (1.5% vs. 0.6%, log rank P = 0.053). Conclusions: This study demonstrates sustained three‐year clinical safety and efficacy of biodegradable polymer‐based sirolimus‐eluting stents when used with six months of dual antiplatelet therapy in a “real‐world” setting. © 2011 Wiley Periodicals, Inc.
Keywords:PCI  percutaneous coronary intervention  drug eluting stent  biodegradable polymer