Impact of renal insufficiency on safety and efficacy of drug‐eluting stents compared to bare‐metal stents at 6 years
Authors:Cihan Simsek MD  Michael Magro MD  Eric Boersma PhD  Yoshinobu Onuma MD  Sjoerd Nauta MSc  Gideon Valstar MSc  Robert‐Jan van Geuns MD  PhD  Willem van der Giessen MD  PhD  Ron van Domburg PhD  Patrick Serruys MD  PhD  Interventional Cardiologists of the Thoraxcenter
Institution:Thoraxcenter, Department of Cardiology, Erasmus MC, Rotterdam, The Netherlands
Abstract:Background : There is few information on the long‐term efficacy and safety of sirolimus‐eluting stents (SES) and paclitaxel‐eluting stents (PES) compared to bare metal stents (BMS) in all‐comer percutaneous coronary intervention (PCI)—patients complicated by renal insufficiency (RI). Objective : Our aim was to assess the 6‐year clinical outcome of PCI‐patients with RI treated exclusively with BMS, SES, or PES in our academic hospital. Methods: A total of 1382 patients, included in three cohorts of consecutive PCI‐patients (BMS = 392; SES = 498; PES = 492), were categorized by creatinine clearance calculated by the Cockroft–Gault formula (normal kidney function ≥ 90; mild RI = 60–89; moderate RI < 60) and systematically followed for the occurrence of major adverse cardiac events (MACE). Results : Mortality rates were significantly higher for patients with moderate RI compared to mild RI and normal kidney function at 6 years (Kaplan–Meier estimate: moderate RI (34%) vs. mild RI (12%), P < 0.001; moderate RI (34%) vs. normal kidney function (8%), P < 0.001). After multivariate Cox‐regression analysis, SES and PES decreased the occurrence of target‐vessel revascularization (TVR) and MACE at 6 years in patients with a normal creatinine clearance compared to BMS adjusted hazard ratio (aHR) = 0.48, 95% CI: 0.28–0.84; aHR = 0.75, 95% CI: 0.57–0.97, respectively] with no significant effect on mortality. Safety‐ and efficacy end points were comparable for the three stent types in patients with mild‐ and moderate renal function. Conclusion : Patients with a normal creatinine clearance had significant improvement in TVR and MACE rates after SES‐ or PES implantation compared to BMS at 6 years. However, there was no superiority of both drug‐eluting stents over BMS in safety and efficacy end points for patients with impaired renal function. © 2012 Wiley Periodicals, Inc.
Keywords:stents  kidney function  percutaneous coronary intervention
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号