Sensitive bioassay for the simultaneous determination of pseudoephedrine and cetirizine in human plasma by liquid-chromatography-ion trap spectrometry
Authors:Tan Zhi-Rong  Ouyang Dong-Sheng  Zhou Gan  Wang Lian-Sheng  Li Zhi  Wang Dan  Zhou Hong-Hao
Institution:Pharmacogenetics Research Institute, Institute of Clinical Pharmacology, Central South University, Xiangya Road 110, Changsha, Hunan 410078, China.
Abstract:A liquid chromatography-ion trap mass spectrometry coupled with electrospray ionization (HPLC-ESI-ion trap mass spectrometry) method for simultaneous determination of cetirizine and pseudoephedrine in human plasma is presented. Chromatographic separation was performed on a Hypurity C18 column (Thermo Hypersil-Keystone 2.1 mm x 150 mm, 5 microm, USA), The mobile phase was composed of 65% methanol and 35% water (contained 0.1% formic acid, 10 mM ammonium formate), which was run with a flow-rate of 0.2 ml/min at 40 degrees C. Quantitation was achieved by monitoring the product ions at m/z 166-->m/z 148 (pseudoephedrine), m/z 389.9-->m/z 201.1 (cetirizine), m/z 264-->m/z 246 (tramadol, IS). The calibration curve of pseudoephedrine and cetirizine was established with standard solutions. The limit of detection for pseudoephedrine and cetirizine each was 5 ng/ml. This simplified analytical method is sensitive, specific and accurate enough for simultaneous determination of pseudoephedrine and cetirizine in human plasma and is successfully applied to the pharmacokinetic study of pseudoephedrine and cetirizine.
Keywords:
本文献已被 ScienceDirect PubMed 等数据库收录!