首页 | 本学科首页   官方微博 | 高级检索  
     


Investigation of health risk assessment sevoflurane on indoor air quality in the operation room in Ahvaz city,Iran
Authors:Abdolkazem Neisi  Masoumeh Albooghobeish  Sahar Geravandi  Hamid Reza Adeli Behrooz  Mohammad Mahboubi  Yusef Omidi Khaniabad
Affiliation:1. Department of Environmental Health Engineering, School of Public Health and Environmental Technologies Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran;2. Department of Anesthesiology, Paramedical School, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran;3. Asadabad School of Medical Sciences, Asadabad, Iran;4. Abadan School of Medical Sciences, Abadan, Iran;5. Health Care System of Karoon, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
Abstract:One of the important wards in educational hospital due to special conditions of patients is operating rooms (ORs). Anesthetic gases sevoflurane among air anesthetic pollutant is very dangerous for health care worker (HCW) and patients. The aim of this study was to associate the concentration of anesthetic toxic sevoflurane gases (ppm) indoor air in Emam, Razi and Golestan teaching hospitals OR during 2016. In the current study, portable pump SKC equipped with sorbent Tube Tenax TA 250?mg was used to sampling and measurements of sevoflurane gases concentration in the ORs. Three detection places were selected for sampling volatile anesthetic gases sevoflurane. In this study, health risks produced by non-cancer causing agents are quantified by calculating the hazard index (HI). Based on result this study, the Emam and Golestan had the lowest and the highest sevoflurane concentrations. According to the results from the current study, level of sevoflurane on indoor air quality in the operation room in Emam, Razi and Golestan hospitals were 2.058, 2.201 and 2.289?ppm, respectively. According result this study HI was under 1.0 and it amount showed that no significant risk of adverse health effects related to exposure to concentration of sevoflurane in Emam, Razi and Golestan teaching hospitals OR during 2016. Result showed that the average concentration of sevoflurane in studied hospitals were more than the standard level (2?ppm) and exposure to this concentration of sevoflurane could be threaten for HCW. Based on result our study, the average level of sevoflurane was significantly higher than that of ORs without standard ventilation in comparison with ORs with standard ventilation system. Performed active for decreasing anesthetic gases can cause decrease health endpoint in OR HCWs and costs. While OR management in ambient air can cause disorders in staffs and causing more spiritual and material costs.
Keywords:Risk assessment  anesthetic  sevoflurane  hospital  operating room  Iran
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号