首页 | 本学科首页   官方微博 | 高级检索  
检索        


Primary prevention of sudden cardiac death by implantable cardioverter-defibrillator therapy in Chinese patients with heart failure: a single-center experience
Authors:CHEN  Tai-bo CHENG  Kang-an GAO  Peng CHENG  Zhong-wei FAN  Jing-bo JIANG  Xiu-chun FANG  Quan
Institution:Department of Cardiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing 100730,China
Abstract:Background An implantable cardioverter-defibrillator (ICD) has been suggested for heart failure patients for primary prevention of sudden cardiac death. However, few data have been reported on the application of ICD as primary prevention of sudden cardiac death in China. We evaluated the value of primary prevention ICD therapy in Chinese patients with heart failure.Methods Thirty-four patients at an average age of (60.2±13.7) years seen in Peking Union Medical College Hospital were treated with ICD implantation for primary prevention of sudden cardiac death from November 2005 to July 2009. Single-chamber ICDs were implanted in 16 (47.0%) cases, and dual-chamber or cardiac resynchronization therapy defibrillators in 18 (53.0%) cases. The patients had an average left ventricular ejection fraction of (26.9±5.5)% (11% to 35%), of which 18 (53.0%) patients had ischemic cardiomyopathy and 16 (47.0%) patients had non-ischemic cardiomyopathy. All patients were followed up at three months after the implantation and every six months thereafter or when prompted by an ICD event.Results There were five (14.7%) deaths, including two of heart failure and three with a non-cardiac course, during an average follow-up of (15.0±11.9) months. Forty-one ICD therapy events were recorded, including 19 (46.3%) appropriate ICD therapies in six patients and 22 (53.7%) inappropriate ICD therapies in four patients with single chamber leads. Inappropriate ICD therapies were mainly due to supraventricular tachyarrhythmias, especially atrial fibrillation. Patients with ischemic cardiomyopathy and non-ischemic cardiomyopathy did not differ in the incidence of either appropriate or inappropriate therapy.Conclusions ICD for primary prevention of sudden cardiac death in China prevents patients from arrhythmia death. Relatively high incidence of inappropriate therapies highlights the importance of an atrial lead.
Keywords:implantable cardioverter-defibrillator  primary prevention  heart failure  Chinese
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《中华医学杂志(英文版)》浏览原始摘要信息
点击此处可从《中华医学杂志(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号