首页 | 本学科首页   官方微博 | 高级检索  
     


Pace-Termination and Pacing for Prevention of Atrial Tachyarrhythmias: Results from a Multicenter Study with an Implantable Device for Atrial Therapy
Authors:CARSTEN W. ISRAEL,M.D.,,BURKHARD HÜ  GL,M.D.,,CHRISTINA UNTERBERG,M.D.,,THOMAS LAWO,M.D.,,INGRID KENNIS,DOUGLAS HETTRICK,STEFAN H. HOHNLOSER,M.D.,
Affiliation:Department of Medicine, J.W. Goethe University, Frankfurt, Germany.
Abstract:INTRODUCTION: Patients with bradycardia requiring permanent pacing frequently suffer from additional atrial tachyarrhythmias (ATs). This study evaluated the safety and efficacy of atrial antitachycardia pacing (ATP) and the performance of pacing for AT prevention implemented into a new pacemaker. METHODS AND RESULTS: In patients with conventional indications for permanent pacing, an investigational DDDRP pacemaker (Medtronic AT500, model 7253) was implanted. The primary study objectives were to determine the safety of overall device functioning and its efficacy in terminating spontaneous AT. A secondary endpoint was to determine the reliability of AT detection. Pacemaker memory functions were used to analyze the impact of dedicated pacing algorithms on AT prevention. In 33 European and Canadian centers, 325 patients were enrolled (mean follow-up 2.3+/-1.3 months). Complication-free survival at 3 months was 88%. In 2,145 episodes stored with atrial electrograms, AT detection was confirmed in 97%. The algorithm for continuous overdrive pacing increased the percentage of atrial pacing to 97%. After ATP activation, 16,683 of 52,468 AT episodes were treated (120 patients). Of these, 8,903 episodes (53%) were terminated successfully by ATP. No proarrhythmic effect of preventive pacing or atrial ATP was observed. Preventive pacing algorithms increased the median percentage of atrial pacing from 62% to 97%. However, the number of AT/AF (atrial fibrillation) episodes (4.1 vs 4.1 per patient per day) and the time in AT/AF (13.7% vs 12.8%) was not significantly different before and after activation of preventive pacing. CONCLUSION: DDDRP pacing with a new system for AT therapy was safe and associated with successful pace-termination of AT in 53% of episodes. Preventive pacing and atrial ATP algorithms represent two new functions that can be implemented safely into pacemaker systems for nonpharmacologic treatment of ATs in patients requiring pacemaker therapy.
Keywords:atrial fibrillation    atrial flutter    antitachycardia pacing    overdrive pacing    dual-chamber pacing    pacemaker algorithm    pacemaker diagnostics
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号