首页 | 本学科首页   官方微博 | 高级检索  
     


Tuned aperture computed tomography (TACT®) for cross-sectional implant site assessment in the posterior mandible
Authors:Behnoush Rashedi  DMD  MS   Donald A. Tyndall  MPH  DDS  PhD   John B. Ludlow  DDS  MS   Nancy R. Chaffee  DDS  MS   Albert D. Guckes  DDS  MS
Affiliation:Department of Restorative Dentistry, School of Dental Medicine, University of Pennsylvania, 4001 Spruce Street, Philadelphia, PA 19104-6003, USA. brashedi@pobox.upenn.edu
Abstract:PURPOSE: This study was designed to optimize a new radiographic modality known as tuned aperture computed tomography (TACT) for cross-sectional imaging of implant sites in human dry mandibles. MATERIALS AND METHODS: Five imaging modalities were compared for image quality and measurement accuracy: (1) conventional hypocycloidal tomograms, (2) TACT images reconstructed using the average method produced using a linear x-ray source movement, (3) TACT images reconstructed using the average method produced using a multidirectional x-ray source movement, (4) minimally reconstructed TACT images without a fiducial marker at the site of interest, and (5) minimally reconstructed TACT images with a fiducial marker at the site of interest. RESULTS: The extended Mantel-Haenszel mean score statistic was used to investigate the influence of modality on subjective image quality. A statistically significant difference for certain types of TACT images and multidirectional tomography (P < 0.0001) was observed. Linear TACT and multmin TACT were rated as significantly better than other image modalities (P < 0.0009), whereas multidirectional tomography was rated as being significantly worse than other radiographic modalities (P < 0.0001). For the quantitative assessment, data were normalized and analyzed statistically through a paired-comparisons t test. For each modality, the accuracy for maximum height and height was significantly different from ground truth (P < 0.05). CONCLUSION: The qualitative data suggest that visibility of structures important to the choice of implant location and dimension were seen better with certain TACT methods. Quantitative differences from ground truth (actual measurements of the bone-absolute truth) were clinically negligible. TACT appears to offer the potential of superior image quality over the status quo.
Keywords:tomograms    digital radiography    mandibular arch    implant imaging
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号