Contrast-enhanced spectral mammography in recalls from the Dutch breast cancer screening program: validation of results in a large multireader,multicase study
Authors:U.?C.?Lalji  author-information"  >  author-information__contact u-icon-before"  >  mailto:u.lalji@mumc.nl"   title="  u.lalji@mumc.nl"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author  author-information__orcid u-icon-before icon--orcid u-icon-no-repeat"  >  http://orcid.org/---"   itemprop="  url"   title="  View OrcID profile"   target="  _blank"   rel="  noopener"   data-track="  click"   data-track-action="  OrcID"   data-track-label="  "  >View author&#  s OrcID profile,I.?P.?L.?Houben,R.?Prevos,S.?Gommers,M.?van?Goethem,S.?Vanwetswinkel,R.?Pijnappel,R.?Steeman,C.?Frotscher,W.?Mok,P.?Nelemans,M.?L.?Smidt,R.?G.?Beets-Tan,J.?E.?Wildberger,M.?B.?I.?Lobbes
Affiliation:1.Departments of Radiology and Nuclear Medicine,Maastricht University Medical Center,Maastricht,The Netherlands;2.Department of Radiology,University Hospital Antwerp, Edegem,Amands,Belgium;3.Department of Radiology,University Medical Center Utrecht,Utrecht,The Netherlands;4.Department of Epidemiology,Maastricht University,Maastricht,The Netherlands;5.Department of Surgery,Maastricht University Medical Center,Maastricht,The Netherlands;6.GROW School for Oncology and Developmental Biology,Maastricht University Medical Centre,Maastricht,The Netherlands
Abstract:

Objectives

Contrast-enhanced spectral mammography (CESM) is a promising problem-solving tool in women referred from a breast cancer screening program. We aimed to study the validity of preliminary results of CESM using a larger panel of radiologists with different levels of CESM experience.

Methods

All women referred from the Dutch breast cancer screening program were eligible for CESM. 199 consecutive cases were viewed by ten radiologists. Four had extensive CESM experience, three had no CESM experience but were experienced breast radiologists, and three were residents. All readers provided a BI-RADS score for the low-energy CESM images first, after which the score could be adjusted when viewing the entire CESM exam. BI-RADS 1-3 were considered benign and BI-RADS 4-5 malignant. With this cutoff, we calculated sensitivity, specificity and area under the ROC curve.

Results

CESM increased diagnostic accuracy in all readers. The performance for all readers using CESM was: sensitivity 96.9 % (+3.9 %), specificity 69.7 % (+33.8 %) and area under the ROC curve 0.833 (+0.188).

Conclusion

CESM is superior to conventional mammography, with excellent problem-solving capabilities in women referred from the breast cancer screening program. Previous results were confirmed even in a larger panel of readers with varying CESM experience.

Key Points

? CESM is consistently superior to conventional mammography ? CESM increases diagnostic accuracy regardless of a readers experience ? CESM is an excellent problem-solving tool in recalls from screening programs