首页 | 本学科首页   官方微博 | 高级检索  
     


Long-term efficacy of implantable cardiac resynchronization therapy plus defibrillator for primary prevention of sudden cardiac death in patients with mild heart failure: an updated meta-analysis
Authors:Wei-Ping?Sun,Chun-Lei?Li,Jin-Cheng?Guo,Li-Xin?Zhang,Ran?Liu,Hai-Bin?Zhang  author-information"  >  author-information__contact u-icon-before"  >  mailto:lhyyzhhbmd@.com"   title="  lhyyzhhbmd@.com"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author,Ling?Zhang  author-information"  >  author-information__contact u-icon-before"  >  mailto:zlilyepi@ccmu.edu.cn"   title="  zlilyepi@ccmu.edu.cn"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author
Affiliation:1.Department of Epidemiology and Health Statistics, School of Public Health,Capital Medical University,Beijing,China;2.Beijing Luhe Hospital,Capital Medical University,Beijing,China;3.Beijing Municipal Key Laboratory of Clinical Epidemiology,Beijing,China
Abstract:Previous studies of implantable cardiac resynchronization therapy plus defibrillator (CRT-D) therapy used for primary prevention of sudden cardiac death have suggested that CRT-D therapy is less effective in patients with mild heart failure and a wide QRS complex. However, the long-term benefits are variable. We performed a meta-analysis of randomized trials identified in systematic searches of MEDLINE, EMBASE, and the Cochrane Database. Three studies (3858 patients) with a mean follow-up of 66 months were included. Overall, CRT-D therapy was associated with significantly lower all-cause mortality than was implantable cardioverter defibrillator (ICD) therapy (OR, 0.78; 95 % CI, 0.63–0.96; P = 0.02; I 2 = 19 %). However, the risk of cardiac mortality was comparable between two groups (OR, 0.74; 95 % CI, 0.53–1.01; P = 0.06). CRT-D treatment was associated with a significantly lower risk of hospitalization for heart failure (OR, 0.67; 95 % CI, 0.50–0.89; P = 0.005; I 2 = 55 %). The composite outcome of all-cause mortality and hospitalization for heart failure was also markedly lower with CRT-D therapy than with ICD treatment alone (OR, 0.67; 95 % CI, 0.57–0.77; P < 0.0001; I 2 = 0 %). CRT-D therapy decreased the long-term risk of mortality and heart failure events in patients with mild heart failure with a wide QRS complex. However, long-term risk of cardiac mortality was similar between two groups. More randomized studies are needed to confirm these findings, especially in patients with NYHA class I heart failure or patients without LBBB.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号