Study of Safety and Efficacy of Novel Sirolimus-Eluting Stent Incorporating Properties of Drug Coating Balloon Among Real World Patients Focusing Younger Population (<35 years)
Authors:Santosh Kumar Sinha  Umeshwar Pandey  Mahmodullah Razi  Awadesh Kumar Sharma  Puneet Aggarwal  Mohit Sachan  Praveen Shukla  Ramesh Thakur
Institution:Department of Cardiology, LPS Institute of Cardiology, Kanpur, India
Abstract:ObjectiveAim of study was to evaluate safety and efficacy of abluminal Mitigator DES + Sirolimus Eluting Stent (Envision Scientific, Surat, India) incorporating novel technology of fusion coating of bioresorbable polymer on both abluminal surface of stent and exposed parts of balloon among real world patients specially focusing younger patients (<35 years).Method1293 patients received Mitigator DES + at LPS Institute of Cardiology, Kanpur, India. Primary outcome was target lesion failure (TLF)- composite of cardiovascular death, target vessel myocardial infarction (TVMI), and target lesion revascularization (TLR) and secondary end points including peri-procedural device failure (failure of stent delivery, change of stent, stent fracture), target vessel failure (TVF), and patient oriented composite end point (POCE)-composite of all deaths, MI, and revascularization and stent thrombosis (ST) at 1-year follow-up.ResultYounger population comprised of 374 (29%) patients. Various indications of interventions were STEMI (n = 614; 47.4%), NSTEMI (n = 416; 32.2%), UA (n = 161; 12.5%), and CCS (n = 102; 7.9%). TLF at 1 year in young and overall population were 3.4% and 3.5% respectively which was driven by TVMI and TLR in 1.3% and 1.1% patients respectively. POCE was observed in 9.5% in each group mainly contributed by any revascularization (3.9%). Device failure was significantly lower in young group than overall population (1.3% vs. 2.2%; p = 0.04) which was mainly driven by stent delivery (1.1%) and edge dissection (0.5%). Definite and probable ST was 1.3% and 1.7% respectively which was not significant. Young patients showed insignificantly lower TLF, TVF, ST and POCE and significantly lower device failure (1.3% vs. 2.6%; p = 0.04) when compared to patients >35 years. On multivariate regression analysis, complex lesion, in-stent restenosis, failure of stent delivery and edge dissection were independent predictors of events or device success rate.ConclusionMitigator DES+™ is safe among real world patients, including young population.
Keywords:Drug-eluting stent  Target lesion failure  Patient oriented composite end point  Stent thrombosis  Percutaneous coronary intervention
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号