首页 | 本学科首页   官方微博 | 高级检索  
检索        


The value of true-FISP sequence added to conventional gadolinium-enhanced MRA of abdominal aorta and its major branches
Authors:Iozzelli Andrea  D'Orta Giovanni  Aliprandi Alberto  Secchi Francesco  Di Leo Giovanni  Sardanelli Francesco
Institution:University of Milan School of Medicine, Department of Medical and Surgical Sciences, Radiology Unit, IRCCS Policlinico San Donato, via Morandi 30, 20097 San Donato Milanese, Milan, Italy
Abstract:To test true-fast imaging with steady-state precession (true-FISP) added to gadolinium-based MR angiography (Gd-MRA) for imaging abdominal aorta and major abdominal vessels, 35 consecutive patients (age 67 ± 11 years) with known or suspected abdominal and/or peripheral vascular disease were studied with sagittal and axial 2D true-FISP during free breathing and coronal 3D fast low-angle shot (FLASH) Gd-MRA (breath-holding, 0.2 mmol/kg of Gd-DOTA at 2 ml/s). We evaluated: suprarenal aorta, celiac trunk, superior mesenteric artery, right renal artery, left renal artery, infrarenal aorta, inferior mesenteric artery, aortic bifurcation/common iliac arteries, lumbar arteries and aortic atheromasia. The possible presence of accessory renal arteries, collateral vasculature and vascular prosthesis/stent was evaluated. A quality four-point score was assigned to each item on both sequences, from 0 (not visible) to 3 (good-to-excellent image quality) and Wilcoxon test was used. Main diagnoses resulted: normal or atheromasic aorta (n = 25); aortic aneurysm (n = 2); patent aorto-iliac surgical prosthesis (n = 2); patent vascular iliac stent (n = 2); aneurysm of iliac artery (n = 1); patent aortic endovascular prosthesis (n = 1); patent aorto-femural bypass (n = 1) and aorto-iliac surgical prosthesis endoleak (n = 1). We also found three patients with accessory renal arteries, two with collateral circulation, and three with surgical aorto-iliac prosthesis. The score of true-FISP (25.9 ± 4.1, median 27) was significantly higher (p = 0.003) than that of Gd-MRA (23.9 ± 3.6, median 24). True-FISP was superior for visualizing inferior mesenteric artery (score 2.5 ± 1.1 vs. 1.0 ± 1.4; p < 0.001) and atheromasic plaques (2.5 ± 1.1 vs. 1.2 ± 1.1; p < 0.001). One collateral vasculature was demonstrated only with Gd-MRA. Summarizing, true-FISP is a power and fast non-breath-hold sequence to be added to Gd-MRA, obtaining an information increase.
Keywords:Magnetic resonance (MR)  Aorta  Magnetic resonance angiography (MRA)
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号