无对比增强MR血管成像与CT血管成像对肾动脉狭窄评价的对照研究
引用本文:王萱,赵欣智,薛华丹,刘梦雨,金征宇.无对比增强MR血管成像与CT血管成像对肾动脉狭窄评价的对照研究[J].磁共振成像,2013,0(4):241-245.
作者姓名:王萱  赵欣智  薛华丹  刘梦雨  金征宇
作者单位:中国医学科学院北京协和医学院北京协和医院放射科,北京,100730
摘    要:目的探讨结合时间-空间双重标记反翻转恢复脉冲(Time-SLIP)序列的无对比增强(non-contrast-enhanced)MR血管造影(MRA)技术在评价肾动脉狭窄(RAS)中的应用,并与CT血管造影(CTA)比较。材料与方法对22例怀疑RAS的患者同期进行MRA和CTA检查。在1.5 T MR扫描仪上,运用结合Time-SLIP技术的冠状面和轴面采集真实稳态自由进动序列(true SSFP)进行肾动脉MRA成像。评价肾动脉MRA图像质量和狭窄程度,并与CTA进行比较。结果共46支肾动脉列入统计,MRA图像质量优秀29例(63%),良好13例(28%),一般4例(9%)。无对比增强MRA与CTA对诊断肾动脉狭窄程度分级结果具有相关性(r=0.991,(P〈0.01)。以CTA为参照标准,MRA诊断明显RAS(狭窄程度≥50%)的敏感度为100%,特异度为97.1%。结论结合Time-SLIP的无对比增强MRA技术可有效用于评价肾动脉狭窄。

关 键 词:磁共振血管造影术  肾动脉梗阻  体层摄影术  X线计算机

Non-contrast-enhanced MR angiography for evaluation renal artery stenosis:comparison with CT angiography
WANG Xuan , ZHAO Xin-zhi , XUE Hua-dan , LIU Meng-yu , JIN Zheng-yu.Non-contrast-enhanced MR angiography for evaluation renal artery stenosis:comparison with CT angiography[J].Chinese Journal of Magnetic Resonance Imaging,2013,0(4):241-245.
Authors:WANG Xuan  ZHAO Xin-zhi  XUE Hua-dan  LIU Meng-yu  JIN Zheng-yu
Institution:WANG Xuan;ZHAO Xin-zhi;XUE Hua-dan;LIU Meng-yu;JIN Zheng-yu;Departments of Radiology,Peking Union Medical College Hospital,Chinese Academy of Medical Sciences;
Abstract:Objective: To explore the application of non-contrast-enhanced magnetic resonance angiography(MRA) with time-spatial labeling inversion pulse(Time-SLIP) for assessment of renal artery stenosis(RAS) comparing with computer tomography angiography(CTA).Materials and Methods: Twenty-two patients 12 men and 10 women,mean age:(47.4±9.2) years] in the suspicion of RAS were evaluated with MRA and CTA in the same period.Coronal and axial true steady-state free-precession(SSFP) sequences with Time-SLIP technique were performed on a 1.5 T MRI system for MRA imaging.Image quality and grade of RAS were evaluated.The UnenhancedMRA images were compared against CTA results.Results: Forty-six renal arteries were included in the statistical analysis.Image quality of MRA was excellent in 63%(29 of 46),good in 28%(13 of 46) and moderate in 9%(four of 46) of patients.The agreement between Time-SLIP MRA and CTA assessments for RAS grading was excellent,with a Spearman rank-order correlation coefficient(r) of 0.991(P0.01).The sensitivity and specificity of non-enhanced-MRA for the detection of significant RAS(≥50%) were 100% and 97.1% using CTA as the gold standard.Conclusion: Non-contrast-enhanced MRA with Time-SLIP is an appropriate method for assessment of renal artery stenosis.
Keywords:Magnetic resonance angiography  Renal artery obstruction  Tomography  X-ray computed