首页 | 本学科首页   官方微博 | 高级检索  
     

冠状动脉粥样硬化性心脏病患者血清基质金属蛋白酶9检测中的质量控制
引用本文:董磊,刘飒,王绿娅. 冠状动脉粥样硬化性心脏病患者血清基质金属蛋白酶9检测中的质量控制[J]. 中国医药, 2010, 5(12): 1120-1121. DOI: 10.3760/cma.j.issn.1673-4777.2010.12.005
作者姓名:董磊  刘飒  王绿娅
作者单位:首都医科大学附属北京安贞医院北京市心肺血管疾病研究所实验研究中心,100029
基金项目:北京市科学技术委员会应用基础研究与战略高技术主题重大项目 
摘    要:目的 通过检测不同类型冠状动脉粥样硬化性心脏病(冠心病)患者血清基质金属蛋白酶9(MMP-9)和质控样本,探讨"即刻性"质控法在科研实验室酶联免疫吸附法(ELISA)中的应用价值.方法 采用ELISA检测冠心病患者血清MMP-9,用"即刻性"质控法进行室内质量控制.结果 ELISA检测MMP-9板内变异系数值≤15%,血清MMP-9质控测定结果SI上限值为1.15,SI下限值为0.625,经与SI值表中第3天的2倍标准差进行比较,均在允许范围之内;与健康对照组、心绞痛患者组相比较,心肌梗死组患者血清MMP-9水平明显升高(P<0.05).结论 "即刻性"质控法对科研实验室是一种行之有效的室内质量控制方法.

关 键 词:基质金属蛋白酶类  酶联免疫吸附试验  "即刻性"质控法

Quality control of serum matrix metalloproteinase-9 detection in patients with coronary artery disease
DONG Lei,LIU Sa,WANG Lu-ya. Quality control of serum matrix metalloproteinase-9 detection in patients with coronary artery disease[J]. China Medicine, 2010, 5(12): 1120-1121. DOI: 10.3760/cma.j.issn.1673-4777.2010.12.005
Authors:DONG Lei  LIU Sa  WANG Lu-ya
Affiliation:DONG Lei(Experimental Research Center Beijing Anzhen Hospital of the Capital Medical University & Beijing Institute of Heart Lung and Blood Vessel Diseases,Beijing 100029, China) LIU Sa(Experimental Research Center Beijing Anzhen Hospital of the Capital Medical University & Beijing Institute of Heart Lung and Blood Vessel Diseases,Beijing 100029, China) WANG Lu-ya(Experimental Research Center Beijing Anzhen Hospital of the Capital Medical University & Beijing Institute of Heart Lung and Blood Vessel Diseases,Beijing 100029, China)
Abstract:Objective To evaluate the "Instant Method" in enzyme-linked immunosorbent assay (ELISA)by detecting matrix metalloproteinase-9 (MMP-9) and to discuss the quality control in the serum in patients with coronary artery disease (CAD). Methods The level of MMP-9 in the serum of patients with CAD was measured by MMP-9 ELISA Kit, and "Instant Method" was used for internal quality control. Results MMP-9 levels were measured in MMP-9 ELISA Kit and the coefficient of variance (CV) was no higher than 15%. The value of SI between 0.625 and 1.15 was in the acceptable range. The level of MMP-9 significantly increased in the serum of the patients with myocardial infarction compared with the health control and angina pectoris. Conclusion "Instant Method" is an effective approach for internal quality control.
Keywords:Matrix metalloproteinases  Enzyme-linked immunosorbent assay  "  Instant method"  quality control
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号