首页 | 本学科首页   官方微博 | 高级检索  
检索        


Real-Time Monitoring of High-Intensity Focused Ultrasound Thermal Therapy Using the Manifold Learning Method
Authors:Parisa Rangraz  Hamid Behnam  Pooya Sobhebidari  Jahan Tavakkoli
Institution:1. Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran;2. Biomedical Engineering Department, School of Electrical Engineering, Iran University of Science and Technology, Tehran, Iran;3. Department of Electrical and Computer Engineering, Ryerson University, Toronto, Ontario, Canada;4. Department of Physics, Ryerson University, Toronto, Ontario, Canada
Abstract:High-intensity focused ultrasound (HIFU) induces thermal lesions by increasing the tissue temperature in a tight focal region. The main ultrasound imaging techniques currently used to monitor HIFU treatment are standard pulse-echo B-mode ultrasound imaging, ultrasound temperature estimation and elastography-based methods. The present study was carried out on ex vivo animal tissue samples, in which backscattered radiofrequency (RF) signals were acquired in real time at time instances before, during and after HIFU treatment. The manifold learning algorithm, a non-linear dimensionality reduction method, was applied to RF signals which construct B-mode images to detect the HIFU-induced changes among the image frames obtained during HIFU treatment. In this approach, the embedded non-linear information in the region of interest of sequential images is represented in a 2-D manifold with the Isomap algorithm, and each image is depicted as a point on the reconstructed manifold. Four distinct regions are chosen in the manifold corresponding to the four phases of HIFU treatment (before HIFU treatment, during HIFU treatment, immediately after HIFU treatment and 10-min after HIFU treatment). It was found that disorganization of the points is achieved by increasing the acoustic power, and if the thermal lesion has been formed, the regions of points related to pre- and post-HIFU significantly differ. Moreover, the manifold embedding was repeated on 2-D moving windows in RF data envelopes related to pre- and post-HIFU exposure data frames. It was concluded that if mean values of the points related to pre- and post-exposure frames in the reconstructed manifold are estimated, and if the Euclidean distance between these two mean values is calculated and the sliding window is moved and this procedure is repeated for the whole image, a new image based on the Euclidean distance can be formed in which the HIFU thermal lesion is detectable.
Keywords:High-intensity focused ultrasound  Thermal lesion detection  Manifold learning  Isomap algorithm
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号