首页 | 本学科首页   官方微博 | 高级检索  
     


Corneal haze after photorefractive keratectomy using different epithelial removal techniques: mechanical debridement versus laser scrape
Authors:Lee Y G  Chen W Y  Petroll W M  Cavanagh H D  Jester J V
Affiliation:Department of Ophthalmology, University of Texas, Southwestern Medical Center at Dallas, Dallas, Texas, USA.
Abstract:PURPOSE: To determine differences of corneal wound healing and haze after photorefractive keratectomy (PRK) using either mechanical epithelial debridement or laser-scrape epithelial removal in human subjects. DESIGN: A 6-month randomized, masked, prospective, paired-eye clinical study. PARTICIPANTS: Twenty eyes in 10 myopic patients treated between March 1999 and May 1999. INTERVENTION: Photorefractive keratectomy treatments with two different epithelial removal techniques. Continuous z-scan of confocal image, termed confocal microscopy through focusing (CMTF), was performed before surgery and at 3 weeks, 6 weeks, 3 months, and 6 months after surgery. MAIN OUTCOMES MEASURES: Epithelial and stromal thickness measurement, achieved stromal ablation depth, and objective assessment of corneal light-backscattering (corneal haze) were obtained from digital image analysis of the CMTF scans. Manifest refraction was also measured. Student's paired t test or two-way repeated-measures analysis of variance after rank transformation were performed to evaluate statistical differences between groups. RESULTS: Comparison of the mean posttreatment spherical equivalent between the two techniques showed no statistically significant difference. In preoperative corneas, mean epithelial thickness was 50.08+/-3.70 microm in the mechanical debridement group and 50.49+/-4.01 microm in laser-scrape group (not significant). For both groups, the epithelium was significantly thinner at 3 weeks, but returned to preoperative values by 6 months, with no difference between groups. Planned stromal ablation depth by PRK was 59.38+/-11.48 microm (39-73 microm; n = 8) in the mechanical group and 57.75 +/- 7.21 microm (48-70 microm; n = 8) in the laser-scrape group. Achieved stromal ablation depth was not significantly different between the two groups. Most importantly, in both groups CMTF-measured corneal haze increased significantly after surgery, peaked at 3 months, and then decreased at 6 months, with no significant difference between groups. (Power = 0.96). CONCLUSIONS: There is no significant difference in the corneal wound healing response between mechanical epithelial debridement versus laser-scrape technique in human myopic eyes undergoing PRK.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号