乳腺癌根治术后特定射野固定钨门分野静态IMRT与VMAT的临床剂量学评估
引用本文:巩汉顺,孟玲玲,解传滨,谷珊珊,王金媛,杨涛,戴相昆,徐寿平. 乳腺癌根治术后特定射野固定钨门分野静态IMRT与VMAT的临床剂量学评估[J]. 中国医疗设备, 2021, 0(4): 113-118
作者姓名:巩汉顺  孟玲玲  解传滨  谷珊珊  王金媛  杨涛  戴相昆  徐寿平
作者单位:中国人民解放军总医院第一医学中心放疗科
基金项目:国家重点研发计划专项(2017YFC0112100);解放军总医院医疗大数据与人工智能研发项目(2019MBD-043)。
摘    要:目的 比较乳腺癌根治术后患者特定射野固定钨门静态调强放疗(Intensity Modulated Radiation Therapy,IMRT)与容积旋转调强放疗(Volumetric Modulated Arc Therapy,VMAT)的剂量学差异.方法 选择24例乳腺癌根治术后患者,分别设计IMRT计划与VMAT...

关 键 词:乳腺癌  调强放疗  容积旋转调强放疗  剂量学

Clinical Dosimetry Evaluation of Static IMRT with Fixed Jaws in Specific Field and VMAT for Breast Cancer after Radical Mastectomy
GONG Hanshun,MENG Lingling,XIE Chuanbin,GU Shanshan,WANG Jinyuan,YANG Tao,DAI Xiangkun,Xu Shouping. Clinical Dosimetry Evaluation of Static IMRT with Fixed Jaws in Specific Field and VMAT for Breast Cancer after Radical Mastectomy[J]. Chinese medical equipment, 2021, 0(4): 113-118
Authors:GONG Hanshun  MENG Lingling  XIE Chuanbin  GU Shanshan  WANG Jinyuan  YANG Tao  DAI Xiangkun  Xu Shouping
Affiliation:(Department of Radiotherapy,First Medical Center of Chinese PLA General Hospital,Beijing 100853,China)
Abstract:Objective To compare the dosimetric difference between static intensity modulated radiation therapy(IMRT)with fixed jaws in specific field and volumetric modulated arc therapy(VMAT)in patients with breast cancer after radical mastectomy.Methods A total of 24 patients with breast cancer after radical mastectomy were selected.IMRT plans and VMAT plans were designed respectively.In the IMRT plans,the supraclavicular area and chest wall area were irradiated by fixed jaw technology in specific fields.The dose parameters of the target areas and organs at risk,the number of machine units and the verification pass rate were compared between the two groups.Results The results of CI and HI in target area of the VMAT plan were better than those of the IMRT plan(P<0.05).The volume parameters in low-dose areas below V5 of contralateral lung in VMAT plan were higher than those in IMRT plan,while the volume parameters of the high-dose area of the affected lung tissue above V10 was significantly lower than the IMRT plan(P<0.05).Heart:the parameters of V5 and above in the VMRT plan for patients with left breast cancer were lower than the IMRT plan.On the other hand,the cardiac parameters of the right breast cancer showed an opposite trend.The average MUs of the VMAT plan was less than that of the IMRT plan,especially for patients with left breast cancer,with significant difference(t=4.18,P<0.05).Conclusion For patients after radical mastectomy for breast cancer,both IMRT plan with fixed jaw in specific field and VMAT plan can meet the clinical needs.The VMAT plan has better target area conformity and uniformity than the IMRT plan,while reduced exposure volume of the high-dose area in lung tissue and other organ at risk,but increased the irradiated range of the lowdose area;at the same time,decreased MUs and shortened the treatment time.
Keywords:breast cancer  intensity modulated radiotherapy  volume modulated arc radiotherapy  dosimetry