Comparison of visual outcomes and reading performance after bilateral implantation of multifocal intraocular lenses with bilateral monofocal intraocular lenses
Authors:Özge Güngör Akku?  Ikbal Seza Petriçli
Institution:1.Vizyon Eye Surgery and Laser Center,Denizli,Turkey;2.Department of Ophthalmology,Etlik Zübeyde Han?m Training and Research Hospital,Ankara,Turkey
Abstract:

Purpose

To compare the visual acuity outcomes, contrast sensitivity function (CS) and reading ability in patients with bilateral multifocal intraocular lenses and patients with bilateral monofocal lenses.

Setting

Vizyon Eye Center, Denizli, Turkey.

Design

Comparative case series.

Methods

Consecutive bilateral cataract patients having implantation of Acriva Reviol MFM 611 multifocal IOLs (Group A) or Acriva BB UD 613 monofocal IOLs (Group B) were included. Parameters analyzed 6 months postoperatively included monocular uncorrected distance (UDVA), binocular uncorrected intermediate (UIVA), binocular uncorrected near (UNVA), CS and bilateral reading performance using MN Read.

Results

The study evaluated 42 eyes in Group A and 40 eyes in Group B. There were no statistically significant differences in UDVA between two groups postoperatively (p = .39). Binocular UIVA and binocular UNVA are better in Group A (p = .00, p = .00). Under photopic and scotopic conditions, contrast sensitivity results were decreased in Group A, especially at high spatial frequencies. No statistically difference were found in reading acuity, critical print size and maximum reading speed between two groups (p = .57, p = .62, p = .22).

Conclusions

This study concludes that multifocal lenses are reliable and efficient replacements for reading glasses since they significantly improve the vision for near or intermediate distance activities.
Keywords:
本文献已被 SpringerLink 等数据库收录!