首页 | 本学科首页   官方微博 | 高级检索  
     

种植体支抗前牵上颌体的三维有限元分析
引用本文:瞿杨,刘健,杨四维,黄跃. 种植体支抗前牵上颌体的三维有限元分析[J]. 实用口腔医学杂志, 2016, 0(1): 58-62. DOI: 10.3969/j.issn.1001-3733.2016.01.012
作者姓名:瞿杨  刘健  杨四维  黄跃
作者单位:四川医科大学口腔医学院,646000
基金项目:自然科学基金青年科学项目(编号81300903);四川省教育厅科研项目(编号川教函[2009]749号09ZA047);泸州市财企科研基金项目(编号泸市财企[2010]41号2010-S -17(3/3))
摘    要:目的:探讨对上颌种植体支抗施加不同大小和方向的前牵引力时颅面复合体骨缝处的应力变化。方法:用螺旋 CT扫描安氏Ⅲ类患者颅面部以获取原始二维图像 DICOM数据,建立颅面复合体的三维有限元模型,种植支抗设计在3223间。模拟前牵引力值1~10 N,1 N 递增,方向平行于眶耳平面向前下呈0°~60°,10°递增,两两组合共70种工况。分析各工况下颅面复合体各骨缝处第一主应力及 Von Miese 等效应力分布情况。结果:牵引角度相同力值不同时,各骨缝应力变化规律相同;牵引力值相同角度不同时,不同区间各骨缝应力变化不同。当牵引角度小于30°时,应力变化分析提示上颌体向前生长并向上旋转;等于30°时上颌体出现向前生长;在40°~50°时,上颌体向前生长方向与牵引方向大致相同;大于50°时,上颌体出现向前生长并向下旋转。结论:种植体支抗眶耳平面向前下30°~50°牵引加载力1~10 N 利于上颌体向前生长。

关 键 词:颅面复合体  上颌体  前牵引  种植体支抗

3-D finite element study on maxillary body protraction using implant anchorage
Abstract:Objective:To explore the stress change rule of craniofacial bone suture and the interface of bone-implant against differ-ent strength and direction of protraction on the implant anchorage in alveolar bone.Methods:The original DICOMdata of 2-D image of craniofacial complex were obtained by high resolution CT scanning.3-D finite element models of craniofacial complex were devel-oped according to the DICOMdata.Forces of 1 -1 0 N inclined at 0 -60°to Frankfort horizontal plane in the anterior and inferior di-rections were respectively applied on the implant anchorage in the alveolar bone at 32 23 .Data of principle stress and Von Mises Stress of each mode of each simulaton was caculated.Results:The change rule of the effectiveness of different force value of protrac-tion in the same direction was the same in different stress zone;that of the same force value of the protraction in differente direction differed in different stress zone.When the protraction angle was less than 30°,the maxillary complex will spin up.In the 30°,the maxillary complex showed the forward growth.Between 40°-50°,the growth direction was the same with the protraction direction. When the protraction angle was more than 50°,the maxillary complex showed down spin.Conclusion:Protraction force of 1 -1 0 N at 30°-50°to Frankfort horizontal plane on implant anchorage in the alveolar bone at 32 23 can induce maxillary complex grow for-ward.
Keywords:Craniofacial complex  Maxillary body  Protraction  Implant anchorage
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号