首页 | 本学科首页   官方微博 | 高级检索  
     


Chipping behaviour of all-ceramic crowns with zirconia framework and CAD/CAM manufactured veneer
Authors:Schmitter M  Mueller D  Rues S
Affiliation:Department of Prosthodontics, Section for Biomaterial Research, University of Heidelberg, 69120 Heidelberg, Germany. Marc_Schmitter@med.uni-heidelberg.de
Abstract:

Objectives

The aim of this in vitro study was to assess the ultimate load to failure of zirconia based crowns veneered with CAD/CAM manufactured ceramic.

Methods

32 identical, anatoform zirconia (Sirona inCoris ZI, mono L F1) frameworks (thickness 0.6 mm) were constructed (Sirona inLab 3.80). Afterwards, 16 crowns were completed using a CAD/CAM manufactured lithium disilicate ceramic veneer (IPS e.max CAD, Ivoclar Vivadent). The remaining 16 frames were veneered using conventional manual layering technique. For the CAD/CAM manufactured veneers, the connection between framework and veneer was accomplished via a glass fusion ceramics. Before fracture tests, half of the specimens underwent thermocycling and chewing simulation (1.2 million chewing cycles, force magnitude Fmax = 108 N). To further investigate the new technique, finite element computations were carried out on the basis of the original geometry.

Results

Nearly all (87.5%) conventionally veneered crowns failed already during chewing simulation, whereas crowns with CAD/CAM manufactured veneers were non-sensitive to artificial ageing. Crowns veneered with lithium disilicate ceramic displayed ultimate loads to failure of about 1600 N.

Conclusion

The CAD/CAM production of veneers for restorations with zirconia framework is a promising way to reduce failures originating from material fatigue.
Keywords:CAD/CAM veneer   Zirconia framework   Ultimate load
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号